沉浸式虚拟现实版简化动作研究手臂测试用于评估卒中后上肢活动
本研究开发了沉浸式虚拟现实版动作研究手臂测试(ARAT-VR),选取原19项中的13项,纳入11名医疗专业人员、30名卒中患者和25名健康对照,评估其内容效度、同时效度、可用性和重测信度。结果显示ARAT-VR与ARAT-13和ARAT-19在患手评分上强相关(r=0.84和r=0.83),可用性(SUS=82.5[75-90])和重测信度(ICC=0.99;p<0.001)优秀,可作为评估卒中患者上肢活动的有效、可用且可靠的工具。
要点
- ARAT-VR选取原19项中的13项,在沉浸式虚拟现实中开发。
- 患手ARAT-VR与ARAT-13(r=0.84)和ARAT-19(r=0.83)强相关。
- 可用性SUS=82.5[75-90],重测信度ICC=0.99(p<0.001)。
核心结论
- ARAT-VR是评估卒中患者上肢活动的有效、可用且可靠的工具,有望提高评估频率、远程评估并改善神经康复。
研究设计与样本
- 开发沉浸式虚拟现实版ARAT(ARAT-VR),从原19项中选取13项。
- 招募11名医疗专业人员、30名卒中患者和25名健康对照者。
- 内容效度由医疗专业人员评分,同时效度采用Spearman相关、Wilcoxon符号秩检验和Bland-Altman图,可用性用系统可用性量表,重测信度用组内相关和Wilcoxon检验。
主要发现
- 医疗专业人员评定13个ARAT-VR项目的中位难度为0[0至-1]至0[0-1],除涉及弹珠的任务外与经典ARAT相当。
- 涉及弹珠的任务难度被评为高于真实任务:拇指-食指和拇指-中指捏取时为1[0-1],拇指-环指捏取时为1[0-2]。
- 患手评分中,ARAT-VR与ARAT-13强相关(r=0.84),与ARAT-19强相关(r=0.83)。
- 可用性SUS=82.5[75-90],重测信度ICC=0.99(p<0.001)。
关键数值与推荐
- ARAT-VR包含13个项目,源自原ARAT的19项。
- 患手ARAT-VR与ARAT-13的相关系数r=0.84,与ARAT-19的r=0.83。
- 可用性SUS中位数82.5[75-90]。
- 重测信度ICC=0.99,p<0.001。
临床怎么用
- ARAT-VR可用于卒中患者上肢活动的评估,具有较好的效度、可用性和重测信度。
- 该工具提供提高评估频率、远程评估的潜力,可补充神经康复。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To plan treatment and measure post-stroke recovery, frequent and time-bounded functional assessments are recommended. With increasing needs for neurorehabilitation advances, new technology based methods, such as virtual reality (VR) have emerged. Here, we developed an immersive VR version of the Action Research Arm Test (ARAT-VR) to complement neurorehabilitation. OBJECTIVE: This study aimed to assess the validity, usability and test-retest reliability of the ARAT-VR among individuals with stroke, healthcare professionals and healthy control subjects (HCS). METHODS: Among the 19 items of the ARAT, 13 items were selected and developed in immersive VR. 11 healthcare professionals, 30 individuals with stroke, and 25 HCS were recruited. Content validity was assessed by asking healthcare professionals to rate the difficulty of performing each item of the ARAT-VR in comparison to the classical Action Research Arm Test (ARAT-19). Concurrent validity was first measured using correlation (Spearman tests) between the ARAT-VR and ARAT-19 scores for the individuals with stroke, and second through correlation and comparison between the scores of the ARAT-VR and the reduced version of the ARAT (ARAT-13) for both individuals with stroke and HCS (Wilcoxon signed rank tests and Bland-Altman plots). Usability was measured using the System Usability Scale. A part of individuals with stroke and HCS were re-tested following a convenient delay to measure test-retest reliability (Intra-class correlation and Wilcoxon tests). RESULTS: Regarding the content validity, median difficulty of the 13 ARAT-VR items (0[0 to - 1] to 0[0-1]) evaluated by healthcare professionals was rated as equivalent to the classical ARAT for all tasks except those involving the marbles. For these, the difficulty was rated as superior to the real tasks (1[0-1] when pinching with the thumb-index and thumb-middle fingers, and 1[0-2] when pinching with thumb-ring finger). Regarding the concurrent validity, for paretic hand scores, there were strong correlations between the ARAT-VR and ARAT-13 (r = 0.84), and between the ARAT-VR and ARAT-19 (r = 0.83). Usability (SUS = 82.5[75-90]) and test-retest reliability (ICC = 0.99; p < 0.001) were excellent. CONCLUSION: The ARAT-VR is a valid, usable and reliable tool that can be used to assess upper limb activity among individuals with stroke, providing potential to increase assessment frequency, remote evaluation, and improve neurorehabilitation. Trial registration https://clinicaltrials.gov/ct2/show/NCT04694833 ; Unique identifier: NCT04694833, Date of registration: 11/24/2020.
引用
- Burton Q, Lejeune T, Dehem S, et al. Performing a shortened version of the Action Research Arm Test in immersive virtual reality to assess post-stroke upper limb activity. J Neuroeng Rehabil. 2022. PMID: 36463219. doi:10.1186/s12984-022-01114-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。