高精度经颅直流电叠加电刺激θ爆发式刺激用于卒中后运动康复:一项试点随机对照试验
结果显示活性组肩内收肌、肘伸肌和拇屈肌痉挛显著降低,多数其他结局指标呈有利于活性组的中至大效应量非显著趋势,仅见电极下轻微皮肤发红,未见严重不良事件。
要点
- HD-tDCS-eTBS联合常规上肢康复对慢性卒中患者安全,仅见轻微皮肤发红。
- 活性组肩内收肌、肘伸肌和拇屈肌痉挛较伪刺激组显著降低。
- 多数其他上肢运动结局呈有利于活性组的非显著趋势,效应量中至大。
核心结论
- HD-tDCS-eTBS安全,且对卒中后上肢运动康复具有治疗潜力。
研究设计与样本
- 两组每次接受20分钟活性或伪HD-tDCS-eTBS联合30分钟常规上肢康复,每周3次共4周。
主要发现
- 活性组肩内收肌痉挛(P = .05)、肘伸肌痉挛(P = .04)和拇屈肌痉挛(P < .01)较伪刺激组显著降低。
- 多数其他结局指标改善呈有利于活性组的非显著趋势,P = .06-.26,ηp2 = 0.06-0.16。
- 除刺激电极下轻微皮肤发红外,未检测到严重不良事件。
关键数值与推荐
- 结局指标包括上肢Fugl-Meyer评估、Wolf运动功能测试、Jebsen-Taylor手功能测试、指鼻试验和改良Ashworth量表,于干预前和干预后立即评估。
临床怎么用
- 可将HD-tDCS-eTBS作为慢性卒中上肢康复的辅助神经调控手段,需关注痉挛改善。
- 治疗参数为每次20分钟HD-tDCS-eTBS联合30分钟常规上肢康复,每周3次共4周。
- 应用时需监测电极下皮肤反应,本试验仅见轻微皮肤发红。
局限性
- 多数运动结局指标改善未达统计学显著。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: High-definition transcranial electrical theta burst superimposing direct current stimulation (HD-tDCS-eTBS) not only incorporates the therapeutic advantages of tDCS and TBS but enhances stimulation focality and practicality. However, the applicability of this innovative neuromodulatory device in post-stroke rehabilitation remains uncertain. OBJECTIVE: This study aimed to assess the efficacy and safety of the HD-tDCS-eTBS on upper extremity (UE) motor function in patients with chronic stroke. METHODS: A patient-blinded, randomized controlled study was conducted. Twenty-four participants were randomly assigned into either the active HD-tDCS-eTBS group or sham HD-tDCS-eTBS group. Both groups received 20 minutes of active/sham HD-tDCS-eTBS combined with 30 minutes of conventional UE rehabilitation each time, 3 times a week for 4 weeks. Outcome measures including the Fugl-Meyer Assessment of Upper Extremity, Wolf Motor Function Test, Jebsen-Taylor Hand Function Test, Finger-Nose Test, and Modified Ashworth Scale were assessed before and immediately after the intervention period. RESULTS: Spasticity of shoulder adductor (P = .05), elbow extensor (P = .04), and thumb flexor (P < .01) were significantly reduced in the active HD-tDCS-eTBS group versus the sham group. Nonsignificant trends in the improvements of most other outcome measures were in favor of the active HD-tDCS-eTBS group with moderate to large effect sizes (P = .06-.26, ηp2 = 0.06-0.16). No severe adverse events except for slight skin redness under the stimulus electrode was detected after the HD-tDCS-eTBS. CONCLUSIONS: Our findings support that HD-tDCS-eTBS is safe and has therapeutic potential for post-stroke UE motor rehabilitation. TRIAL REGISTRATION: ClinicalTrials.gov (ID: NCT04278105).
引用
- Huang YJ, Wang SM, Chen C, et al. High-Definition Transcranial Direct Current with Electrical Theta Burst on Post-Stroke Motor Rehabilitation: A Pilot Randomized Controlled Trial. Neurorehabil Neural Repair. 2022. PMID: 36047662. doi:10.1177/15459683221121751
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。