沉浸式虚拟现实箱块测试在卒中患者手部灵活性评估中的并发效度
结果显示BBT-VR在卒中患者患手(r=0.89)和非患手(r=0.76)及健康人优势手(r=0.58)和非优势手(r=0.68)均与BBT呈强相关,重测信度ICC>0.8,可用性接近优秀(SUS=79±12.34%)。结论认为BBT-VR是可用、有效且可靠的评估工具,并提供运动学参数。
要点
- BBT-VR与BBT在卒中患者患手呈强相关(r=0.89,p<0.001)。
- BBT-VR重测信度ICC>0.8,可用性SUS=79±12.34%。
- BBT-VR平均移动块数比BBT少30%至40%。
核心结论
- BBT-VR是可用、有效且可靠的评估手部灵活性的工具,适用于卒中患者和健康人,并提供运动学参数。
主要发现
- 卒中患者患手BBT与BBT-VR块数相关r=0.89(p<0.001),非患手r=0.76(p<0.001);健康人优势手r=0.58(p<0.01),非优势手r=0.68(p<0.001)。
- BBT-VR重测信度ICC>0.8(p<0.001),可用性SUS=79±12.34%。
- 参与者BBT-VR平均移动块数比BBT少30%至40%。
- 健康人运动学参数Vmean=0.22±0.086 ms-1、Vpeak=0.96±0.341 ms-1、SPARC=-3.31±0.862,卒中患者Vmean=0.12±0.052 ms-1、Vpeak=0.60±0.202 ms-1、SPARC=-5.04[-7.050 to -3.682]。
关键数值与推荐
- 并发效度以BBT与BBT-VR移动块数的相关系数评估,重测信度以ICC评估,可用性以系统可用性量表评估。
临床怎么用
- BBT-VR可用于卒中患者手部灵活性的客观评估,并提供运动学参数如平均速度、峰值速度和平滑度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: After a stroke, experts recommend regular monitoring and kinematic assessments of patients to objectively measure motor recovery. With the rise of new technologies and increasing needs for neurorehabilitation, an interest in virtual reality has emerged. In this context, we have developed an immersive virtual reality version of the Box and Block Test (BBT-VR). The aim of this study was to assess the concurrent validity of the BBT-VR among patients with stroke and healthy participants. METHODS: Twenty-three healthy participants and 22 patients with stroke were asked to perform the classical Box and Block Test (BBT) and BBT-VR three times with both hands. Concurrent validity was assessed through correlations between these two tests and reliability of the BBT-VR through correlation on test-retest. Usability of the BBT-VR was also evaluated with the System Usability Scale. Hand kinematic data extracted from controller's 3D position allowed to compute mean velocity (Vmean), peak velocity (Vpeak) and smoothness (SPARC). RESULTS: Results showed strong correlations between the number of blocks displaced with the BBT and the BBT-VR among patients with stroke for affected (r = 0.89; p < 0.001) and less-affected hands (r = 0.76; p < 0.001) and healthy participants for dominant (r = 0.58; p < 0.01) and non-dominant hands (r = 0.68; p < 0.001). Reliability for test-retest was excellent (ICC > 0.8; p < 0.001) and usability almost excellent (System Usability Scale = 79 ± 12.34%). On average participants moved between 30 and 40% less blocks during the BBT-VR than during the BBT. Healthy participants demonstrated significantly higher kinematic measures (Vmean = 0.22 ± 0.086 ms-1; Vpeak = 0.96 ± 0.341 ms-1; SPARC = - 3.31 ± 0.862) than patients with stroke (Vmean = 0.12 ± 0.052 ms-1; Vpeak = 0.60 ± 0.202 ms-1; SPARC = - 5.04[- 7.050 to - 3.682]). CONCLUSION: The BBT-VR is a usable, valid and reliable test to assess manual dexterity, providing kinematic parameters, in a population of patients with stroke and healthy participants. Trial registration http://www.clinicaltrials.gov ; Unique identifier: NCT04694833, Date of registration: 11/24/2020.
引用
- Everard G, Otmane-Tolba Y, Rosselli Z, et al. Concurrent validity of an immersive virtual reality version of the Box and Block Test to assess manual dexterity among patients with stroke. J Neuroeng Rehabil. 2022. PMID: 35065678. doi:10.1186/s12984-022-00981-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。