文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

前列腺超低分放疗在线自适应无AI的C臂直线加速器临床经验

Clinical Experience in Prostate Ultrahypofractionated Radiation Therapy With an Online Adaptive Method.
PubMed 文献 · Pract Radiat Oncol · 2021-10-17

该研究在西班牙巴塞罗那Quirónsalud医院开展,纳入前18例接受在线自适应放疗(oART)的前列腺癌患者,采用7×6.1 Gy超低分方案,在2台常规Varian C臂直线加速器上手工完成靶区与危及器官的每日适配及全量再优化。对126次自适应治疗分次进行剂量学比较,自适应计划靶区覆盖显著优于非自适应计划(97.1 vs 90.4,P < .001),非自适应时35%分次未达最佳覆盖,自适应则所有分次均满足全部危及器官剂量约束。

要点

  • 无AI辅助的oART在C臂直线加速器上技术可行
  • 自适应计划靶区覆盖优于非自适应(97.1 vs 90.4,P < .001)
  • 自适应使全部分次满足危及器官剂量约束

核心结论

  • 本研究所描述的oART技术在不具备人工智能能力的C臂直线加速器上技术可行,据作者所知为首个包含全量再计划的前列腺癌oART临床经验。

研究设计与样本

  • 单中心前瞻性描述性研究,纳入西班牙巴塞罗那Quirónsalud医院首批18例接受oART的前列腺癌患者,采用7×6.1 Gy超低分方案,在2台常规Varian C臂直线加速器上治疗。

主要发现

  • 18例患者共126次自适应治疗分次中,自适应计划与非自适应计划的靶区覆盖存在显著差异(97.1 vs 90.4,P < .001),支持自适应。
  • 无在线自适应时,35%的分次未达到前列腺最佳覆盖。
  • 自适应可在所有治疗分次中改善靶区覆盖并满足全部危及器官剂量约束。

关键数值与推荐

  • 超低分放疗方案为7×6.1 Gy。
  • 每次治疗将计划CT与当日锥形束CT刚性配准,手工将靶区(前列腺)和危及器官映射并适配至当日解剖,参考计划复制至锥形束CT后行全量再优化。
  • 非自适应计划通过模拟标准流程的软组织对齐方式在当日锥形束CT上重新计算。

临床怎么用

  • 对于前列腺超低分放疗,可在无AI支持的常规C臂直线加速器上实施在线自适应全量再计划以改善靶区覆盖并满足危及器官约束。

局限性

  • 样本量仅为前18例患者,随访与临床结局未在摘要中报告。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to describe the feasibility of the online adaptive radiation therapy (oART) method developed at the Hospital Quirónsalud Barcelona for prostate cancer, using a standard C-arm linear accelerator (linac) and without the support of artificial intelligence. METHODS AND MATERIALS: The first 18 patients treated at the Hospital Quirónsalud Barcelona with the developed oART method were included. An ultrahypofractionated radiation therapy scheme consisting of 7 × 6.1 Gy was used. Patients were treated on 2 conventional Varian C-arm linacs. For each patient, a reference plan based on a planning computed tomography (pCT) scan was generated using the Eclipse system. On each treatment session, the pCT scan was rigidly registered with the daily cone beam computed tomography (CT) scan. The pCT-based target (prostate) and organs at risk were mapped onto the cone beam CT images and manually adapted to take into account the anatomy of the day. The reference plan was then copied to the cone beam CT scan, and a full reoptimization was done for the current anatomy (adapted plan). For each treatment session, the unaltered reference plan was recomputed on the daily cone beam CT scan by mimicking the soft-tissue alignment performed per our standard procedure (nonadapted plan). Over the 126 adapted sessions from the 18 patients, a dosimetric comparison of adapted against nonadapted plans was done. RESULTS: A significant difference in the target coverage was found between the adapted and nonadapted plans (97.1 vs 90.4; P < .001) in favor of adapting. Without online adaptation, the optimal coverage of the prostate was not attained in 35% of fractions. Adapting allows for the improvement of the target coverage with compliance of all organ-at-risk dose constraints in all treatment fractions. CONCLUSIONS: The oART technique described in this study is technically feasible with a C-arm linac. To our knowledge, this is the first clinical experience with oART for prostate cancer including full replanning and delivered with a C-arm linac without artificial intelligence capability.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。