文献速递乳腺癌放疗

乳腺切线束能量与手术床至皮肤距离对保乳治疗后局部复发的影响

Breast Tangent Beam Energy, Surgical Bed-to-Skin Distance and Local Recurrence After Breast-Conserving Treatment.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2021-10-23

这项基于人群的研究纳入10,083例接受保乳手术及全乳放疗的浸润性乳腺癌患者,中位随访11.1年。

要点

  • 切缘阳性、脉管侵犯、广泛导管内成分及未用内分泌治疗与复发风险升高相关。

核心结论

  • 使用较高能量的乳腺切线束与局部复发风险增加无关,包括手术床靠近皮肤者。

研究设计与样本

  • 基于人群的队列研究,纳入2002至2011年接受保乳手术及辅助全乳放疗(无 bolus 或 beam spoiler)的新诊断浸润性乳腺癌患者10,083例。
  • 主要终点为局部复发的累积发生率(CILR),中位随访11.1年。
  • 全队列多因素分析纳入平均束能量、年龄、T分期、淋巴结状态、总分期、脉管侵犯、分级、切缘状态、广泛导管内成分、乳腺癌亚型、内分泌治疗及化疗。
  • 在3,359例勾画手术床的患者中另行多因素分析纳入手术床至皮肤距离。

主要发现

  • 10年CILR:4 MV组3.1%(95%CI 1.6-5.4),6 MV组2.8%(95%CI 2.4-3.3),>6至10 MV组4.2%(95%CI 3.4-5.3),>10 MV组2.6%(95%CI 1.9-3.5)。
  • 局部复发风险升高与切缘阳性、脉管侵犯、广泛导管内成分及未接受内分泌治疗相关。

临床怎么用

  • 对于接受保乳手术及全乳放疗的患者,可依据剂量均匀性及晚期乳腺毒性选择较高能量切线束,而不必担心增加局部复发风险。
  • 手术床靠近皮肤并非选用较高能量切线束的禁忌。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Higher energy (>6 MV) photons reduce dose inhomogeneity with breast tangent beams, thereby reducing late breast toxicity, but skin and superficial tissue sparing by higher energy beams raises concerns about local recurrence (LR) risk. This study aimed to determine whether beam energy and surgical bed-to-skin distance affect LR. METHODS AND MATERIALS: This population-based study included newly diagnosed invasive breast cancers without skin involvement (pT1-4a, any-N, M0) treated with breast-conserving surgery and adjuvant whole breast radiation therapy without bolus or beam spoilers. The primary endpoint was the cumulative incidence of LR (CILR). Multivariable analysis (MVA) included mean beam energy, age, T-stage, nodal status, overall stage, lymphovascular invasion (LVI), grade, margin status, extensive intraductal component (EIC), breast cancer subtype, hormone therapy, and chemotherapy. In a subgroup with contoured surgical beds, another MVA included surgical bed-to-skin distance. RESULTS: The cohort consisted of 10,083 women treated from 2002 to 2011: 327 with 4 MV, 6006 with 6 MV, 2083 with >6 to 10 MV, and 1667 with >10 MV tangents. The median follow-up time was 11.1 years. The 10-year CILR was 3.1% (95% confidence interval [CI], 1.6-5.4) with 4 MV, 2.8% (2.4-3.3) with 6 MV, 4.2% (3.4-5.3) with >6 to 10 MV, and 2.6% (1.9-3.5) with >10 MV. On MVA of the entire cohort, LR risk was increased with positive margins, LVI, EIC, and lack of hormone therapy, but was not associated with beam energy (hazard ratio [HR], 1.01; 95% CI, 0.96-1.05; P = .8). On MVA of 3359 patients with contoured surgical beds, LR risk was not associated with surgical bed-to-skin distance (HR, 1.00; 95% CI, 0.99-1.02; P = .8). CONCLUSIONS: Use of higher breast tangent beam energies is not associated with increased risk of LR, including in cases with surgical beds that are close to the skin.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Nichol A, Narinesingh D, Wade L, et al. Breast Tangent Beam Energy, Surgical Bed-to-Skin Distance and Local Recurrence After Breast-Conserving Treatment. Int J Radiat Oncol Biol Phys. 2021. PMID: 34699929. doi:10.1016/j.ijrobp.2021.10.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。