文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

前列腺金标影像配准的观察者间偏差研究

Investigation of the clinical inter-observer bias in prostate fiducial marker image registration between CT and MR images.
PubMed 文献 · Radiat Oncol · 2021-08-16

本研究让4名经验丰富的观察者对42例局限期前列腺癌患者的CT与MR图像进行金标(GFM)配准,评估观察者间偏差。结果显示金标识别绝对差异0.0–3.0 mm,CTV质心位移最大3.1 mm,位移≥1 mm、≥2 mm、≥3 mm分别占46%、18%、4%,观察者间CTV位移无统计学显著差异。

要点

  • 金标配准存在观察者间偏差,单个患者CTV位移可达3 mm
  • CTV质心位移≥1 mm占46%,≥2 mm占18%,≥3 mm占4%
  • 结果支持去除跨模态配准、转向MRI-only工作流程

核心结论

  • 局限期前列腺癌CT-MR金标配准在单个患者水平存在观察者间偏差,CTV位移可达3 mm,提示临床金标配准存在不确定性。

研究设计与样本

  • 4名经验丰富的观察者对42例局限期前列腺癌患者的CT与MR图像先行手动金标识别、再行基于标志点的配准,并与临床基线配准比较。

主要发现

  • 观察者间金标识别绝对差异范围为0.0–3.0 mm。
  • 相对临床基线的CTV质心最大位移为3.1 mm。
  • CTV质心位移≥1 mm、≥2 mm、≥3 mm分别占46%、18%、4%。
  • 观察者间CTV位移无统计学显著差异。
  • CTV的中位DICE指数为0.94(范围0.70–1.00),中位Hausdorff距离为2.5 mm(范围0.7–8.7)。

临床怎么用

  • 应认识到临床金标配准存在观察者间不确定性,单个患者CTV位移可达3 mm。
  • 结果支持在放疗流程中去除跨模态配准并转向MRI-only工作流程。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Inter-modality image registration between computed tomography (CT) and magnetic resonance (MR) images is associated with systematic uncertainties and the magnitude of these uncertainties is not well documented. The purpose of this study was to investigate the potential uncertainty of gold fiducial marker (GFM) registration for localized prostate cancer and to estimate the inter-observer bias in a clinical setting. METHODS: Four experienced observers registered CT and MR images for 42 prostate cancer patients. Manual GFM identification was followed by a landmark-based registration. The absolute difference between observers in GFM identification and the displacement of the clinical target volume (CTV) was investigated. The CTV center of mass (CoM) vector displacements, DICE-index and Hausdorff distances for the observer registrations were compared against a clinical baseline registration. The time allocated for the manual registrations was compared. RESULTS: Absolute difference in GFM identification between observers ranged from 0.0 to 3.0 mm. The maximum CTV CoM displacement from the clinical baseline was 3.1 mm. Displacements larger than or equal to 1 mm, 2 mm and 3 mm were 46%, 18% and 4%, respectively. No statistically significant difference was detected between observers in terms of CTV displacement. Median DICE-index and Hausdorff distance for the CTV, with their respective ranges were 0.94 [0.70-1.00] and 2.5 mm [0.7-8.7]. CONCLUSIONS: Registration of CT and MR images using GFMs for localized prostate cancer patients was subject to inter-observer bias on an individual patient level. A CTV displacement as large as 3 mm occurred for individual patients. These results show that GFM registration in a clinical setting is associated with uncertainties, which motivates the removal of inter-modality registrations in the radiotherapy workflow and a transition to an MRI-only workflow for localized prostate cancer.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Persson E, Emin S, Scherman J, et al. Investigation of the clinical inter-observer bias in prostate fiducial marker image registration between CT and MR images. Radiat Oncol. 2021. PMID: 34399806. doi:10.1186/s13014-021-01865-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。