文献速递乳腺癌放疗放疗物理与技术

紫外墨水纹身对比传统深色墨水纹身用于乳腺癌放疗的前瞻性随机对照试验

A Prospective Randomized Controlled Trial to Compare the Use of Conventional Dark-Ink Tattoo and Ultraviolet-Ink Tattoo for Patients Undergoing Breast Radiation Therapy.
PubMed 文献 · Pract Radiat Oncol · 2021-08-17

结果显示两组平均摆位误差无统计学显著差异(P=NS),各时间点体像调查反应相似(P=NS),多数患者对紫外墨水纹身满意且自信,绝大多数工作人员认为紫外墨水对摆位时间影响极小且易于定位。

要点

  • 紫外墨水纹身与传统深色墨水纹身的初始摆位误差无统计学显著差异(P=NS)。
  • 两组在CT模拟、放疗最后一周和放疗后6周的体像调查反应相似(P=NS)。
  • 多数患者对纹身外观满意且不因纹身感到性吸引力下降,工作人员认为紫外墨水对摆位时间影响极小。

核心结论

  • 使用紫外墨水纹身未发现摆位精度差异,可在对现有工作流程影响极小的情况下临床实施。
  • 患者对紫外墨水纹身的使用表达了高满意度和自信。

研究设计与样本

  • 患者在CT模拟时接受指定纹身,比较初始治疗摆位偏移,并在CT模拟、放疗最后一周和放疗后6周三个时间点进行9项体像调查。
  • 收集CT和治疗工作人员关于摆位时间和挑战的反馈。

主要发现

  • 患者队列中位年龄为46岁。
  • 传统深色墨水组平均摆位误差为 inferior 0.11 cm、left 0.01 cm、posterior 0.11 cm,紫外墨水组为 superior 0.01 cm、right 0.01 cm、posterior 0.06 cm,两组间无统计学显著差异(P=NS)。
  • 两组在所有时间点的体像调查反应相似(P=NS)。
  • 放疗后6周,多数患者(深色墨水82.3% vs 紫外墨水88.2%)未因纹身感到性吸引力下降。
  • 放疗后6周,两组患者对纹身外观满意且不因选择衣服而谨慎(82.4% vs 88.2%;P=NS)。

临床怎么用

  • 紫外墨水纹身可作为传统深色墨水纹身的替代选择,不损害摆位精度且对工作流程影响小。
  • 患者对紫外墨水纹身的高满意度和自信支持其临床推广。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Permanent tattoo marks used in radiation therapy remain for the duration of treatment and essentially for the rest of the patient's life. This study compared the initial positioning setup errors and body image perception between patients with ultraviolet (UV) and conventional dark ink tattoos. METHODS AND MATERIALS: Thirty-four patients from February 2018 to March 2019, who underwent radiation therapy (RT) to the breast or chest wall for ductal carcinoma in situ or breast cancer were prospectively recruited and randomized (1:1) to receive either conventional dark ink or UV ink tattoos. Each patient received the assigned tattoos during computed tomography (CT) simulation and initial treatment setup shifts were compared. A 9-item body-image survey was administered to all patients at 3 time points: CT simulation, last week of RT, and 6 weeks post-RT. Feedback from CT and treatment staff in terms of setup time and challenges were collated. RESULTS: The median age of the patient cohort was 46 years old. No statistically significant difference was observed between the mean setup errors for the conventional dark ink group (0.11 cm inferior, 0.01 cm left, 0.11 cm posterior) and UV ink group (0.01 cm superior, 0.01 cm right, 0.06 cm posterior; P = NS). Similar responses were observed in the body-image survey between the 2 groups across all time points (P = NS). The majority of the patients (dark ink 82.3% vs UV ink 88.2%) did not feel less sexually attractive as a result of the tattoo at 6 weeks post-RT. At 6 weeks post-RT, patients in both groups were satisfied with the appearance of the tattoo and did not feel cautious about their choice of clothes (82.4% vs 88.2%; P = NS). In addition, 88.6% of staff (n = 35) felt minimum effect of UV ink on the overall setup time, and 94.3% found no difficulty localizing the UV ink tattoos during patient positioning. CONCLUSIONS: No difference in setup accuracy was found using UV ink tattoos, and it could be implemented clinically with minimal effect on the existing workflow. Patients expressed high satisfaction and self-confidence with the use of UV ink tattoos.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Lim LH, Pang EPP, Sultana R, et al. A Prospective Randomized Controlled Trial to Compare the Use of Conventional Dark-Ink Tattoo and Ultraviolet-Ink Tattoo for Patients Undergoing Breast Radiation Therapy. Pract Radiat Oncol. 2021. PMID: 34411756. doi:10.1016/j.prro.2021.08.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。