固定铅门调强放疗用于T形食管癌的剂量学与生物学评估
结果显示FJ IMRT在靶区均匀性和适形性上与其它计划基本等效,在肺低-中等剂量参数及NTCP上较JT IMRT和SJ IMRT有统计学显著改善,且改善与PTV-Cinferior长度呈中度正相关(相关系数0.523–0.797)。
要点
- FJ IMRT在肺低剂量体积保护上优于JT VMAT。
- FJ IMRT的肺NTCP及低-中等剂量参数较JT IMRT和SJ IMRT显著改善。
- 改善与PTV-Cinferior长度呈中度正相关(r=0.523–0.797)。
核心结论
- FJ IMRT技术对T形食管癌患者在减少肺组织低剂量体积方面具有优势。
研究设计与样本
- 比较指标包括剂量学参数、TCP、NTCP、MUs、delivery time及gamma通过率。
- 分析PTV-Cinferior长度与剂量学参数及肺组织NTCP的相关性。
主要发现
- 四种计划中靶区的均匀性和适形性基本等效。
- FJ IMRT较JT IMRT和SJ IMRT在肺NTCP及低-中等剂量参数上有统计学显著改善,改善与PTV-Cinferior长度呈中度正相关(相关系数0.523–0.797)。
- FJ IMRT在低剂量体积的肺保护上优于JT VMAT。
- FJ IMRT的MUs(888±99)和delivery time(516.1±54.7 s)与JT IMRT(937±194,522±5.6 s)相似,但高于SJ IMRT(713±137,488.8±45.2 s)和JT VMAT(517±59,263.7±43.3 s)。
临床怎么用
- 对于T形食管癌放疗,可考虑采用FJ IMRT以降低肺低剂量照射体积。
- PTV-Cinferior较长者可能从FJ IMRT的肺保护中获益更明显。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To evaluate the dosimetric and biological benefits of the fixed-jaw (FJ) intensity-modulated radiation therapy (IMRT) technique for patients with T-shaped esophageal cancer. METHODS: FJ IMRT plans were generated for thirty-five patients and compared with jaw tracking (JT) IMRT, static jaw (SJ) IMRT and JT volumetric modulated arc therapy (VMAT). Dosimetric parameters, tumor control probability (TCP) and normal tissue complication probability (NTCP), monitor units (MUs), delivery time and gamma passing rate, as a measure of dosimetric verification, were compared. The correlation between the length of PTV-C below the upper boundary of lung tissue (PTV-Cinferior) and dosimetric parameters and NTCP of the lung tissue were analyzed. RESULTS: The homogeneity and conformity of the target in the four plans were basically equivalent. When compared to the JT IMRT and SJ IMRT plans, FJ IMRT plan led to a statistically significant improvement in the NTCP and low-middle dosimetric parameters of the lung, and the improvement had a moderately positive correlation with the length of PTV-Cinferior, with a correlation coefficient ranging from 0.523 to 0.797; the FJ IMRT plan exhibited better lung sparing in low-dose volumes than the JT VMAT plan. The FJ IMRT plan had similar MUs (888 ± 99) and delivery times (516.1 ± 54.7 s) as the JT IMRT plan (937 ± 194, 522 ± 5.6 s) but higher than SJ IMRT (713 ± 137, 488.8 ± 45.2 s) and JT VMAT plan (517 ± 59, 263.7 ± 43.3 s). CONCLUSIONS: The FJ IMRT technique is superior in reducing the low-dose volumes of lung tissues for patients with T-shaped esophageal cancer.
引用
- Chen H, Huang Y, Wang H, et al. Dosimetric comparison and biological evaluation of fixed-jaw intensity-modulated radiation therapy for T-shaped esophageal cancer. Radiat Oncol. 2021. PMID: 34412656. doi:10.1186/s13014-021-01882-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。