文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

1.5T MR-Linac放疗中精囊腺分次内运动研究

Seminal vesicle intrafraction motion during the delivery of radiotherapy sessions on a 1.5 T MR-Linac.
PubMed 文献 · Radiother Oncol · 2021-07-20

结果显示SV运动幅度大于前列腺且随时间增加,采用5mm等向扩展(SV)和3mm扩展(前列腺)可实现99%分次内覆盖率。

要点

  • 精囊腺分次内运动幅度大于前列腺,且随治疗时间延长而增加。
  • 左右精囊腺采用5mm等向扩展、前列腺采用3mm扩展可达99%覆盖率。
  • 三维电影磁共振与精囊腺追踪在 beam-on 期间可行,可支持分次内再计划。

核心结论

  • 精囊腺分次内运动较前列腺更大且随时间增加,需针对性扩展边界。
  • 5mm等向扩展用于左右精囊腺、3mm用于前列腺可实现99%分次内覆盖率。

研究设计与样本

  • 全程采集三维电影磁共振,采用经验证的软组织对比追踪算法分别测定双侧精囊腺运动。

主要发现

  • 共分析247分次 beam-on 期间(约10分钟)的精囊腺运动。
  • 精囊腺运动离散度大于前列腺,在前后和头脚平移方向尤为明显。
  • 精囊腺绕左右轴旋转显著大于前列腺。

关键数值与推荐

  • 左右精囊腺采用5mm等向扩展、前列腺采用3mm扩展时,分次内覆盖概率达99%。

临床怎么用

  • 追踪方法可作为快速再计划算法的输入,支持分次内计划自适应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate seminal vesicle (SV) intrafraction motion using cinematic magnetic resonance imaging (cine-MR) during the delivery of online adaptive MR-Linac radiotherapy fractions, in preparation of MR-guided extremely hypofractionated radiotherapy for intermediate to high-risk prostate cancer patients. MATERIAL AND METHODS: Fifty prostate cancer patients were treated with 5 × 7.25 Gy on a 1.5 Tesla MR-Linac. 3D Cine-MR imaging was started simultaneously and acquired over the full beam-on period. Intrafraction motion in this cine-MR was determined for each SV separately with a previously validated soft-tissue contrast-based tracking algorithm. Motion statistics and coverage probability for the SVs and prostate were determined based on the obtained results. RESULTS: SV motion was automatically determined during the beam-on period (approx. 10 min) for 247 fractions. SV intrafraction motion shows larger spread than prostate intrafraction motion and increases over time. This difference is especially evident in the anterior and cranial translation directions. Significant difference in rotation about the left-right axis was found, with larger rotation for the SVs than the prostate. Intra-fraction coverage probability of 99% can be achieved when using 5 mm isometric expansion for the left and right SV and 3 mm for the prostate. CONCLUSION: This is the first study to investigate SV intrafraction motion during MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and SV tracking during RT is feasible with beam-on. The tracking method as described may be used as input for a fast replanning algorithm, which allows for intrafraction plan adaptation.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Muinck Keizer DM, Willigenburg T, der Voort van Zyp JRN, et al. Seminal vesicle intrafraction motion during the delivery of radiotherapy sessions on a 1.5 T MR-Linac. Radiother Oncol. 2021. PMID: 34293410. doi:10.1016/j.radonc.2021.07.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。