直肠癌新辅助治疗中基于锥形束CT在线自适应放疗的可行性
结果显示治疗机平均占用34分钟,自适应流程(含计划生成和验证)平均20分钟,50%分次需手动调整靶区体积,计划质量、靶区覆盖和患者依从性均优秀。结论认为基于CBCT的在线自适应放疗对直肠癌可行。
要点
- 基于CBCT的在线自适应放疗对直肠癌术前5×5 Gy放疗可行
- 治疗机平均占用34分钟,自适应计划流程平均20分钟
- 50%分次需手动调整靶区体积,计划质量和靶区覆盖优秀
核心结论
- 基于CBCT的在线自适应放疗在直肠癌术前放疗中首次临床经验显示可行。
研究设计与样本
- 基于单次计划CT生成参考计划,在线自适应流程包括获取CBCT、变形配准生成合成CT、AI辅助轮廓适应、生成新计划并用第二和第三CBCT验证。
- PTV margin除总CTV头脚边界为8 mm外,所有方向均为5 mm。
主要发现
- 治疗机平均占用时间为34分钟。
- 获取CBCT、评估调整轮廓、创建新计划及验证CTV平均耗时20分钟,包括照射和疗后验证为26分钟。
- 50%的分次需要手动调整靶区体积,计划质量、靶区覆盖和患者依从性均优秀。
关键数值与推荐
- PTV margin:所有方向5 mm,总CTV头脚边界8 mm。
- 处方剂量:5×5 Gy术前放疗。
临床怎么用
- 直肠癌术前放疗可采用基于CBCT的在线自适应工作流,需多学科团队在场并预留约34分钟治疗机时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Online adaptive radiotherapy has the potential to reduce toxicity for patients treated for rectal cancer because smaller planning target volumes (PTV) margins around the entire clinical target volume (CTV) are required. The aim of this study is to describe the first clinical experience of a Conebeam CT (CBCT)-based online adaptive workflow for rectal cancer, evaluating timing of different steps in the workflow, plan quality, target coverage and patient compliance. METHODS: Twelve consecutive patients eligible for 5 × 5 Gy pre-operative radiotherapy were treated on a ring-based linear accelerator with a multidisciplinary team present at the treatment machine for each fraction. The accelerator is operated using an integrated software platform for both treatment planning and delivery. In all directions for all CTVs a PTV margin of 5 mm was used, except for the cranial/caudal borders of the total CTV where a margin of 8 mm was applied. A reference plan was generated based on a single planning CT. After aligning the patient the online adaptive procedure started with acquisition of a CBCT. The planning CT scan was registered to the CBCT using deformable registration and a synthetic CT scan was generated. With the support of artificial intelligence, structure guided deformation and the synthetic CT scan contours were adapted by the system to match the anatomy on the CBCT. If necessary, these contours were adjusted before a new plan was generated. A second and third CBCT were acquired to validate the new plan with respect to CTV coverage just before and after treatment delivery, respectively. Treatment was delivered using volumetric modulated arc treatment (VMAT). All steps in this process were defined and timed. RESULTS: On average the timeslot needed at the treatment machine was 34 min. The process of acquiring a CBCT, evaluating and adjusting the contours, creating the new plan and verifying the CTV on the CBCT scan took on average 20 min. Including delivery and post treatment verification this was 26 min. Manual adjustments of the target volumes were necessary in 50% of fractions. Plan quality, target coverage and patient compliance were excellent. CONCLUSIONS: First clinical experience with CBCT-based online adaptive radiotherapy shows it is feasible for rectal cancer. Trial registration Medical Research Involving Human Subjects Act (WMO) does not apply to this study and was retrospectively approved by the Medical Ethics review Committee of the Academic Medical Center (W21_087 # 21.097; Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, The Netherlands).
引用
- de Jong R, Visser J, van Wieringen N, et al. Feasibility of Conebeam CT-based online adaptive radiotherapy for neoadjuvant treatment of rectal cancer. Radiat Oncol. 2021. PMID: 34301300. doi:10.1186/s13014-021-01866-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。