中国多中心研究:胸段食管癌根治性放疗靶区勾画间的观察者间变异

Interobserver variability in target volume delineation in definitive radiotherapy for thoracic esophageal cancer: a multi-center study from China.
PubMed 文献 · Radiat Oncol · 2021-06-09

常规勾画下淋巴结大体肿瘤体积(GTV-N)的IOV最显著,最小DSC为0.37(95%CI 0.32-0.42);遵循勾画方案后GTV-N最小DSC提升至0.64(95%CI 0.45-0.83,P=0.005),而GTV-T与CTV的DSC在多数病例中保持不变。

要点

  • 常规勾画时GTV-N的观察者间变异最大,最小DSC仅0.37。
  • 遵循统一勾画方案后GTV-N的DSC显著提升至0.64(P=0.005)。
  • GTV-T在常规勾画中一致性较高,方案干预后多数病例DSC保持稳定。

核心结论

  • 胸段食管癌根治性放疗靶区勾画存在观察者间变异,但通过强制性干预可显著减少并控制该变异。

研究设计与样本

  • 采用Dice相似系数(DSC)分析和量化靶区体积的变异。

主要发现

  • 常规勾画中GTV-N的观察者间变异在所有病例中最显著,最小DSC为0.37(95%CI 0.32-0.42),其次为CTV,而GTV-T显示较高一致性。
  • 遵循方案后,GTV-N的最小DSC提升至0.64(95%CI 0.45-0.83,P=0.005),但GTV-T和CTV的DSC在多数病例中保持不变。

临床怎么用

  • 对于胸段食管癌根治性放疗,应制定并强制执行统一的靶区勾画方案,以降低GTV-N等靶区的观察者间变异,提高多中心研究的一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the interobserver variability (IOV) in target volume delineation of definitive radiotherapy for thoracic esophageal cancer (TEC) among cancer centers in China, and ultimately improve contouring consistency as much as possible to lay the foundation for multi-center prospective studies. METHODS: Sixteen cancer centers throughout China participated in this study. In Phase 1, three suitable cases with upper, middle, and lower TEC were chosen, and participants were asked to contour a group of gross tumor volume (GTV-T), nodal gross tumor volume (GTV-N) and clinical target volume (CTV) for each case based on their routine experience. In Phase 2, the same clinicians were instructed to follow a contouring protocol to re-contour another group of target volume. The variation of the target volume was analyzed and quantified using dice similarity coefficient (DSC). RESULTS: Sixteen clinicians provided routine volumes, whereas ten provided both routine and protocol volumes for each case. The IOV of routine GTV-N was the most striking in all cases, with the smallest DSC of 0.37 (95% CI 0.32-0.42), followed by CTV, whereas GTV-T showed high consistency. After following the protocol, the smallest DSC of GTV-N was improved to 0.64 (95% CI 0.45-0.83, P = 0.005) but the DSC of GTV-T and CTV remained constant in most cases. CONCLUSION: Variability in target volume delineation was observed, but it could be significantly reduced and controlled using mandatory interventions.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Chang X, Deng W, Wang X, et al. Interobserver variability in target volume delineation in definitive radiotherapy for thoracic esophageal cancer: a multi-center study from China. Radiat Oncol. 2021. PMID: 34107984. doi:10.1186/s13014-020-01691-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。