文献速递头颈部肿瘤放疗消化道肿瘤放疗放疗物理与技术

深度学习自动勾画危及器官对鼻咽癌和直肠癌剂量学的影响

The dosimetric impact of deep learning-based auto-segmentation of organs at risk on nasopharyngeal and rectal cancer.
PubMed 文献 · Radiat Oncol · 2021-06-23

几何评价显示两系统在腮腺、颞叶、晶状体和眼方面表现相似,FD在视神经、口腔、喉和股骨头更优,UIH在膀胱更优。剂量学分析表明,与人工勾画计划相比,多数靶区和OAR剂量体积指标无显著差异,仅左颞叶最大剂量在FD计划中有显著差异(p=0.05);几何指标与剂量学差异之间大多无强相关性。

要点

  • 深度学习自动勾画对鼻咽癌和直肠癌多数靶区及OAR剂量体积指标无显著影响。
  • FD系统在视神经、口腔、喉、股骨头几何表现更优,UIH在膀胱更优。
  • 仅左颞叶最大剂量在FD计划与人工计划间有显著差异(p=0.05)。

核心结论

  • 基于深度学习的OAR自动勾画对鼻咽癌和直肠癌的多数PTV和OAR剂量体积指标影响不显著。
  • 大多数OAR的自动勾画几何指标与剂量学差异之间未观察到强相关性。

研究设计与样本

  • 几何评价采用Hausdorff距离、平均一致距离、Dice相似系数和Jaccard指数;剂量学评价采用剂量体积指标和3D伽马分析。
  • 采用Spearman相关分析探究剂量学差异与几何指标的相关性。

主要发现

  • FD和UIH在腮腺、颞叶、晶状体和眼几何表现相似(DICE,p>0.05)。
  • OAR_FD在视神经、口腔、喉和股骨头几何表现更优(DICE,p<0.05);OAR_UIH在膀胱更优(DICE,p<0.05)。
  • Plan_FD和Plan_UIH与Plan_Manual相比,多数PTV和OAR剂量体积指标差异无统计学意义。
  • 唯一显著剂量学差异为FD计划与人工计划间左颞叶最大剂量(p=0.05)。
  • 仅发现股骨头平均剂量与其HD指数显著相关(R=0.4,p=0.01),无OAR显示剂量学差异与所有四个几何指标强相关。

关键数值与推荐

  • 几何评价指标包括HD、MDA、DICE和Jaccard指数。
  • 剂量学评价采用剂量体积指标和3D伽马分析。
  • 统计学显著性阈值p<0.05。

临床怎么用

  • 对于鼻咽癌和直肠癌放疗,深度学习自动勾画OAR可替代人工勾画用于计划设计,对多数剂量体积指标影响不显著。
  • 需关注左颞叶最大剂量等个别指标可能存在的显著差异。
  • 几何指标不能完全预测剂量学差异,临床应结合剂量学验证。

局限性

  • 仅评估了两套特定自动勾画系统。
  • 未报告几何指标与剂量学差异间相关性的其他细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the dosimetric impact of deep learning-based auto-segmentation of organs at risk (OARs) on nasopharyngeal and rectal cancer. METHODS AND MATERIALS: Twenty patients, including ten nasopharyngeal carcinoma (NPC) patients and ten rectal cancer patients, who received radiotherapy in our department were enrolled in this study. Two deep learning-based auto-segmentation systems, including an in-house developed system (FD) and a commercial product (UIH), were used to generate two auto-segmented OARs sets (OAR_FD and OAR_UIH). Treatment plans based on auto-segmented OARs and following our clinical requirements were generated for each patient on each OARs sets (Plan_FD and Plan_UIH). Geometric metrics (Hausdorff distance (HD), mean distance to agreement (MDA), the Dice similarity coefficient (DICE) and the Jaccard index) were calculated for geometric evaluation. The dosimetric impact was evaluated by comparing Plan_FD and Plan_UIH to original clinically approved plans (Plan_Manual) with dose-volume metrics and 3D gamma analysis. Spearman's correlation analysis was performed to investigate the correlation between dosimetric difference and geometric metrics. RESULTS: FD and UIH could provide similar geometric performance in parotids, temporal lobes, lens, and eyes (DICE, p > 0.05). OAR_FD had better geometric performance in the optic nerves, oral cavity, larynx, and femoral heads (DICE, p < 0.05). OAR_UIH had better geometric performance in the bladder (DICE, p < 0.05). In dosimetric analysis, both Plan_FD and Plan_UIH had nonsignificant dosimetric differences compared to Plan_Manual for most PTV and OARs dose-volume metrics. The only significant dosimetric difference was the max dose of the left temporal lobe for Plan_FD vs. Plan_Manual (p = 0.05). Only one significant correlation was found between the mean dose of the femoral head and its HD index (R = 0.4, p = 0.01), there is no OARs showed strong correlation between its dosimetric difference and all of four geometric metrics. CONCLUSIONS: Deep learning-based OARs auto-segmentation for NPC and rectal cancer has a nonsignificant impact on most PTV and OARs dose-volume metrics. Correlations between the auto-segmentation geometric metric and dosimetric difference were not observed for most OARs.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Guo H, Wang J, Xia X, et al. The dosimetric impact of deep learning-based auto-segmentation of organs at risk on nasopharyngeal and rectal cancer. Radiat Oncol. 2021. PMID: 34162410. doi:10.1186/s13014-021-01837-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。