颅底头颈癌调强质子治疗后脑影像改变的剂量与LET混合效应模型
本研究纳入15例颅底头颈癌接受调强质子治疗(IMPT)后出现脑影像改变(RAIC)的患者,在体素水平分析剂量与剂量平均线性能量转移(LETd)和RAIC的关联。单因素和多因素混合效应逻辑回归均显示剂量和LETd与RAIC显著相关,多因素模型AUC达0.95。LETd升高在多数患者中增加RAIC风险,提示临床计划中应考虑评估LETd。
要点
- 剂量和LETd均与IMPT后RAIC显著相关,多因素模型AUC为0.95。
- LETd=1 keV/µm时,60 Gy和70 Gy的RAIC估计概率分别为4%和29%。
- LETd=2和5 keV/µm时,TD15分别估计为63.6 Gy和50.1 Gy。
核心结论
- 剂量和LETd与IMPT后RAIC显著相关,LETd效应对部分患者可能具有临床意义,临床治疗计划中应考虑评估LETd。
研究设计与样本
- 对15例IMPT后出现RAIC的颅底头颈癌患者,将T1加权MRI对比增强区勾画并配准至计划CT,提取体素水平蒙特卡洛计算的剂量和LETd分布,采用单因素和多因素混合效应逻辑回归建模。
主要发现
- 单因素和多因素分析均发现RAIC与剂量和LETd总体显著相关,患者异质性大,剂量和LETd的随机效应标准差分别为1.81(1.30-2.72)和2.68(1.93-4.93)。
- 单因素剂量反应模型和多因素模型的AUC分别为0.93和0.95。
- 多数患者中LETd升高与RAIC风险增加相关。
- LETd=1 keV/µm时,60 Gy和70 Gy的RAIC估计概率分别为4%(95%CI 0%-0.44%)和29%(95%CI 0.01%-0.92%)。
- LETd=2和5 keV/µm时,TD15分别估计为63.6 Gy和50.1 Gy。
临床怎么用
- 对于颅底头颈癌IMPT计划,除剂量外应评估LETd分布,尤其关注高LETd区域与脑组织的重叠。
局限性
- 样本量较小(15例),患者异质性大,需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Intensity modulated proton therapy (IMPT) could yield high linear energy transfer (LET) in critical structures and increased biological effect. For head and neck cancers at the skull base this could potentially result in radiation-associated brain image change (RAIC). The purpose of the current study was to investigate voxel-wise dose and LET correlations with RAIC after IMPT. METHODS AND MATERIALS: For 15 patients with RAIC after IMPT, contrast enhancement observed on T1-weighted magnetic resonance imaging was contoured and coregistered to the planning computed tomography. Monte Carlo calculated dose and dose-averaged LET (LETd) distributions were extracted at voxel level and associations with RAIC were modelled using uni- and multivariate mixed effect logistic regression. Model performance was evaluated using the area under the receiver operating characteristic curve and precision-recall curve. RESULTS: An overall statistically significant RAIC association with dose and LETd was found in both the uni- and multivariate analysis. Patient heterogeneity was considerable, with standard deviation of the random effects of 1.81 (1.30-2.72) for dose and 2.68 (1.93-4.93) for LETd, respectively. Area under the receiver operating characteristic curve was 0.93 and 0.95 for the univariate dose-response model and multivariate model, respectively. Analysis of the LETd effect demonstrated increased risk of RAIC with increasing LETd for the majority of patients. Estimated probability of RAIC with LETd = 1 keV/µm was 4% (95% confidence interval, 0%, 0.44%) and 29% (95% confidence interval, 0.01%, 0.92%) for 60 and 70 Gy, respectively. The TD15 were estimated to be 63.6 and 50.1 Gy with LETd equal to 2 and 5 keV/µm, respectively. CONCLUSIONS: Our results suggest that the LETd effect could be of clinical significance for some patients; LETd assessment in clinical treatment plans should therefore be taken into consideration.
引用
- Engeseth GM, He R, Mirkovic D, et al. Mixed Effect Modeling of Dose and Linear Energy Transfer Correlations With Brain Image Changes After Intensity Modulated Proton Therapy for Skull Base Head and Neck Cancer. Int J Radiat Oncol Biol Phys. 2021. PMID: 34153379. doi:10.1016/j.ijrobp.2021.06.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。