左乳腺癌放疗中心脏与肺部剂量随摆位不确定性的变化
该研究对30例左乳腺癌患者在深吸气屏气(DIBH)或自由呼吸(FB)下给予50 Gy(2 Gy/次)放疗,模拟深部或尾侧方向每2.5 mm的等中心偏移,评估心脏、左心室、左前降支及同侧肺剂量参数变化。结果显示DIBH下深部切向摆位偏差5 mm可使心脏、左心室、左前降支和同侧肺剂量分别偏移达49.4%、56.4%、90.3%和26.1%,而尾侧摆位无显著差异。
要点
- DIBH下深部切向摆位偏差5 mm可使心脏平均剂量增加约50%、同侧肺增加约25%。
- DIBH下心脏剂量分布变化较FB更温和,但深部偏差仍显著影响心脏、左心室和左前降支剂量。
- 尾侧摆位偏差未显示显著剂量差异。
核心结论
- DIBH下深部切向摆位偏差超过5 mm动作水平时,心脏和同侧肺平均剂量预计分别增加约50%和25%。
研究设计与样本
- 对30例左乳腺癌患者分别采用DIBH或FB技术给予50 Gy(2 Gy/次)放疗。
- 假设误差来自深部或尾侧平移轴,将等中心从原始切向对准每2.5 mm偏移以模拟摆位不确定性。
- 评估心脏、左心室、左前降支和同侧肺的剂量参数变化。
主要发现
- 原始计划中DIBH下心脏和同侧肺平均剂量分别为2.0 ± 1.1 Gy和3.7 ± 1.4 Gy,FB下分别为8.4 ± 1.3 Gy和7.8 ± 1.5 Gy。
- DIBH下心脏剂量分布变化较FB更温和。
- 深部切向摆位越深,心脏、左心室、左前降支和同侧肺剂量越差,5 mm DIBH摆位下偏移分别达49.4%、56.4%、90.3%和26.1%。
- 尾侧摆位未显示显著剂量差异。
- DIBH多重比较中,所有7.5 mm深部摆位下心脏(p = 0.025)、左心室(p = 0.049)和左前降支(p = 0.025)平均剂量差异有统计学意义。
关键数值与推荐
- DIBH下深部切向摆位偏差5 mm时,心脏、左心室、左前降支和同侧肺剂量偏移分别达49.4%、56.4%、90.3%和26.1%。
- DIBH下7.5 mm深部摆位时心脏(p = 0.025)、左心室(p = 0.049)和左前降支(p = 0.025)平均剂量差异显著。
临床怎么用
- 左乳腺癌DIBH放疗中应严格控制深部切向摆位误差,5 mm动作水平即可导致心脏和同侧肺剂量明显增加。
- 尾侧摆位误差对剂量影响较小,可优先关注深部方向摆位准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Breast radiotherapy set-up is often uncertain. Actual dose distribution to normal tissues could be different from planned dose distribution. The objective of this study was to investigate such difference in dose distribution according to the extent of set-up error in breast radiotherapy. MATERIALS AND METHODS: A total of 50 Gy with fraction size of 2 Gy was given to 30 left breasts with different set-ups applying a deep inspiration breath holding (DIBH) or a free breathing (FB) technique. Under the assumption that errors might come from translational axes of deep or caudal directions, the isocenter was shifted from the original tangential alignment every 2.5 mm to simulate uncertainty of deep and caudal tangential set-up in DIBH and FB. Changes were evaluated for dosimetric parameters for the heart, the left ventricle (LV), the left anterior descending coronary artery (LAD), and the ipsilateral lung. RESULTS: On the original plan, mean doses of heart and ipsilateral lung were 2.0 ± 1.1 Gy and 3.7 ± 1.4 Gy in DIBH and 8.4 ± 1.3 Gy and 7.8 ± 1.5 Gy in FB, respectively. The change of dose distribution for the heart in DIBH was milder than that in FB. The deeper the tangential set-up, the worse the heart, LV, LAD, and ipsilateral lung doses, showing as much as 49.4%, 56.4%, 90.3%, and 26.1% shifts, respectively, in 5 mm DIBH setup. The caudal set-up did not show significant dose difference. In multiple comparison of DIBH, differences of mean dose occurred in all 7.5 mm deep set-ups for the heart (p = 0.025), the LV (p = 0.049), and LAD (p = 0.025) in DIBH. CONCLUSIONS: To correct set-up error over indicated limitation for deep tangential set-up in DIBH at 5 mm action level, mean heart and ipsilateral lung doses are expected to increase approximately 50% and 25%, respectively.
引用
- Park S, Rim CH, Yoon WS, et al. Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer. Radiat Oncol. 2021. PMID: 33879201. doi:10.1186/s13014-021-01806-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。