文献速递乳腺癌放疗放疗物理与技术

部分乳腺照射的分次内运动取决于治疗时长

Intrafraction motion during partial breast irradiation depends on treatment time.
PubMed 文献 · Radiother Oncol · 2021-03-31

结果显示呼吸所需边界仅0.3-0.6 mm,而漂移所需边界随分次时长增加,8分钟以内1.0 mm足够,32分钟需2.5 mm,24分钟约为8分钟的两倍。

要点

  • APBI分次内呼吸运动影响有限,所需边界仅0.3-0.6 mm。
  • 靶区漂移使所需边界随分次时长增加,24分钟约为8分钟的两倍。
  • 分次≤8分钟时1.0 mm边界足够,32分钟时需2.5 mm。

核心结论

  • 补偿分次内运动所需的CTV-PTV边界随分次时长延长而增大,主要归因于靶区漂移,呼吸运动影响有限。

主要发现

  • 呼吸所需边界为0.3-0.6 mm。
  • 漂移所需边界随首次定位成像后时间延长而增大:分次总时长至8分钟时1.0 mm足够,32分钟时需2.5 mm。
  • 考虑呼吸运动的技术可将边界减少0.1 mm。
  • 漂移存在向尾侧、内侧和后侧的系统性趋势,补偿此趋势可在边界上增加0.7 mm。
  • 24分钟分次的所需边界是8分钟分次的两倍。

关键数值与推荐

  • 分次时长≤8分钟时,补偿漂移的边界1.0 mm足够。
  • 分次时长32分钟时,补偿漂移的边界需2.5 mm。
  • 呼吸运动所需边界0.3-0.6 mm;考虑呼吸运动的技术可减少边界0.1 mm。
  • 补偿系统性漂移趋势可在边界上增加0.7 mm。

临床怎么用

  • 行APBI时应关注分次治疗时长,分次延长时需相应增大CTV-PTV边界以补偿靶区漂移。
  • 采用考虑呼吸运动的技术可小幅减少边界。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: As the prognosis of early-stage breast cancer patients is excellent, prevention of radiation-induced toxicity has become crucial. Reduction of margins compensating for intrafraction motion reduces non-target dose. We assessed motion of the tumor bed throughout APBI treatment fractions and calculated CTV-PTV margins for breathing and drift. METHODS: This prospective clinical trial included patients treated with APBI on a Cyberknife with fiducial tracking. Paired orthogonal kV images made throughout the entire fraction were used to extract the tumor bed position. The images used for breathing modelling were used to calculate breathing amplitudes. The margins needed to compensate for breathing and drift were calculated according to Engelsman and Van Herk respectively. RESULTS: Twenty-two patients, 110 fractions and 5087 image pairs were analyzed. The margins needed for breathing were 0.3-0.6 mm. The margin for drift increased with time after the first imaging for positioning. For a total fraction duration up to 8 min, a margin of 1.0 mm is sufficient. For a fraction of 32 min, 2.5 mm is needed. Techniques that account for breathing motion can reduce the margin by 0.1 mm. There was a systematic trend in the drift in the caudal, medial and posterior direction. To compensate for this, 0.7 mm could be added to the margins. CONCLUSIONS: The margin needed to compensate for intrafraction motion increased with longer fraction duration due to drifting of the target. It doubled for a fraction of 24 min compared to 8 min. Breathing motion has a limited effect.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Hoekstra N, Habraken S, Swaak-Kragten A, et al. Intrafraction motion during partial breast irradiation depends on treatment time. Radiother Oncol. 2021. PMID: 33798609. doi:10.1016/j.radonc.2021.03.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。