方向依赖边界计算方法用于共识勾画指南制定
本研究提出一种量化临床靶区(CTV)在临床医生指定方向上边界及观察者间变异性的新方法,并应用于11例非脊柱骨转移病例。结果显示骨内和骨外推荐边界分别为7.0 mm和8.0 mm,骨内和骨外边界的中位变异系数分别为0.59和0.48。该方法可在未来共识CTV勾画研究中用于生成方向特异性边界建议。
要点
- 提出按肿瘤播散方向量化CTV边界及观察者间变异的新算法。
- 非脊柱骨转移病例中,骨内和骨外推荐边界分别为7.0 mm和8.0 mm。
- 骨内和骨外边界的中位变异系数分别为0.59和0.48。
核心结论
- 所提算法可依据邻近解剖结构生成方向特异性边界建议,并量化指定方向上的观察者间变异性。
研究设计与样本
- 方法学研究,将新算法应用于11例非脊柱骨转移病例,计算骨内和骨外疾病各方向的共识CTV边界。
主要发现
- 骨内和骨外推荐边界分别为7.0 mm和8.0 mm。
- 骨内和骨外边界的中位变异系数分别为0.59和0.48。
关键数值与推荐
- 推荐边界取所有病例各播散路径的中位数。
- 观察者间分歧以骨内和骨外边界变异系数的中位数量化。
临床怎么用
- 该方法可用于未来共识CTV勾画研究,生成与邻近解剖相关的方向依赖性边界建议。
局限性
- 原文未报告。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Clinical target volume (CTV) contouring guidelines are frequently developed through studies in which experts contour the CTV for a representative set of cases for a given treatment site and the consensus CTVs are analyzed to generate margin recommendations. Measures of interobserver variability are used to quantify agreement between experts. In cases where an isotropic margin is not appropriate, however, there is no standard method to compute margins in specified directions that represent possible routes of tumor spread. Moreover, interobserver variability metrics are often measures of volume overlap that do not account for the dependence of disagreement on direction. To aid in the development of consensus contouring guidelines, this study demonstrates a novel method of quantifying CTV margins and interobserver variability in clinician-specified directions. METHODS: The proposed algorithm was applied to 11 cases of non-spine bone metastases to compute the consensus CTV margin in each direction of intraosseous and extraosseous disease. The median over all cases for each route of spread yielded the recommended margins. The disagreement between experts on the CTV margin was quantified by computing the median of the coefficients of variation for intraosseous and extraosseous margins. RESULTS: The recommended intraosseous and extraosseous margins were 7.0 mm and 8.0 mm, respectively. The median coefficient of variation quantifying the margin disagreement between experts was 0.59 and 0.48 for intraosseous and extraosseous disease. CONCLUSIONS: The proposed algorithm permits the generation of margin recommendations in relation to adjacent anatomy and quantifies interobserver variability in specified directions. This method can be applied to future consensus CTV contouring studies.
引用
- Lawrence LSP, Chin LCL, Chan RW, et al. Method of computing direction-dependent margins for the development of consensus contouring guidelines. Radiat Oncol. 2021. PMID: 33849576. doi:10.1186/s13014-021-01799-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。