文献速递消化道肿瘤放疗放疗物理与技术

胰腺癌SBRT中基准标记几何重复性及个体化呼吸屏气边界设计

Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Deep Inspiration Breath Hold for Stereotactic Body Radiation Therapy for Pancreatic Cancer.
PubMed 文献 · Adv Radiat Oncol · 2021-01-22

本研究分析20例接受深吸气屏气SBRT的胰腺癌患者,在模拟定位时采集3次额外屏气CT扫描量化基准标记位置变异并设计个体化屏气边界,治疗中每分次平均采集5次屏气CBCT评估标记位置变异。结果显示屏气间变异在头脚方向最大,ITV较GTV增加21.0%±8.6%,覆盖>95%标记位置所需PTV边界ITV为2mm(LR/AP)和4mm(SI),GTV为4mm(LR/AP)和6mm(SI)。

要点

  • 屏气间基准标记变异在头脚方向最显著,治疗时平均最大变异达3.1±1.4mm。
  • 模拟定位多次屏气CT可量化重复性并设计个体化屏气边界。
  • 基于ITV的PTV边界小于基于GTV的边界,覆盖>95%标记位置。

核心结论

  • 屏气间变异不可忽略,尤其在头脚方向;模拟定位多次屏气CT有助于量化重复性并设计个体化屏气边界。

研究设计与样本

  • 分析20例连续接受深吸气屏气SBRT的胰腺癌患者,模拟定位时在增强计划CT后立即采集3次额外屏气扫描,治疗中每分次平均采集5次屏气CBCT。

主要发现

  • 模拟定位基准标记平均变异和最大变异分别为:左右方向0.9±0.5mm和1.5±0.8mm,前后方向0.9±0.4mm和1.4±0.4mm,头脚方向1.5±0.9mm和2.1±1.0mm。
  • 治疗时基准标记平均变异和最大变异分别为:左右方向1.2±0.4mm和2.0±0.7mm,前后方向1.1±0.4mm和1.8±0.6mm,头脚方向1.9±1.0mm和3.1±1.4mm。
  • ITV较GTV alone增加21.0%±8.6%。
  • 覆盖>95%基准标记位置所需PTV边界:ITV在左右和前后方向为2mm、头脚方向为4mm;GTV在左右和前后方向为4mm、头脚方向为6mm。

关键数值与推荐

  • 覆盖>95%基准标记位置所需PTV边界:基于ITV时左右和前后方向为2mm、头脚方向为4mm;基于GTV时左右和前后方向为4mm、头脚方向为6mm。

临床怎么用

  • 胰腺癌深吸气屏气SBRT中可考虑模拟定位时采集多次屏气CT以量化屏气重复性并设计个体化屏气边界。
  • 基于ITV设计PTV边界较基于GTV所需边界更小,有助于在保证覆盖的同时减少正常组织照射。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: In patients undergoing stereotactic body radiation therapy (SBRT) for pancreatic adenocarcinoma, the reproducibility of tumor positioning between deep-inspiration breath holds is unclear. We characterized this variation with fiducials at simulation and treatment and investigated whether a patient-specific breath-hold (PSBH) margin would help account for intrafraction variation at treatment. METHODS AND MATERIALS: We analyzed 20 consecutive patients with pancreatic cancer who underwent SBRT with deep-inspiration breath holds. At simulation, 3 additional breath-hold scans were acquired immediately after the contrast-enhanced planning computed tomography (CT) scan and used to quantify the mean and maximum variations in the simulation fiducial position (Sim_Var avg and Sim_Var max ), as well as to design the internal target volume (ITV) incorporating a PSBH margin. RESULTS: At treatment, a mean of 5 breath-hold cone beam CT (CBCT) scans were acquired per fraction for each patient to quantify the mean and maximum variations in the treatment fiducial position (Tx_Var avg and Tx_Var max ). Various planning target volume (PTV) margins on the gross tumor volume (GTV) versus ITV were evaluated using CBCT scans, with the goal of >95% of fiducials being covered at treatment. The Sim_Var avg and Sim_Var max were 0.9 ± 0.5 mm and 1.5 ± 0.8 mm in the left-right (LR) direction, 0.9 ± 0.4 mm and 1.4 ± 0.4 mm in the anteroposterior (AP) direction, and 1.5 ± 0.9 mm and 2.1 ± 1.0 mm in the superoinferior (SI) direction, respectively. The Tx_Var avg and Tx_Var max were 1.2 ± 0.4 mm and 2.0 ± 0.7 mm in the LR direction, 1.1 ± 0.4 mm and 1.8 ± 0.6 mm in the AP direction, and 1.9 ± 1.0 mm and 3.1 ± 1.4 mm in the SI direction, respectively. The ITV was increased by 21.0% ± 8.6% compared with the GTV alone. The PTV margin necessary to encompass >95% of the fiducial locations was 2 mm versus 4 mm in both LR and AP and 4 mm versus 6 mm in SI for the ITV and the GTV, respectively. CONCLUSIONS: The interbreath-hold variation is not insignificant, especially in the SI direction. Acquiring multiple breath-hold CT scans at simulation can help quantify the reproducibility of the interbreath hold and design a PSBH margin for treatment.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Han-Oh S, Hill C, Kang-Hsin Wang K, et al. Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Deep Inspiration Breath Hold for Stereotactic Body Radiation Therapy for Pancreatic Cancer. Adv Radiat Oncol. 2021. PMID: 33732963. doi:10.1016/j.adro.2021.100655