文献速递乳腺癌放疗放疗物理与技术

热塑膜与商用胸罩固定下垂乳房放疗摆位精度的回顾性队列比较

Comparing Accuracy of Thermoplastic Mask versus Commercial Bra for the Immobilization of Pendulous Breast During Radiation Therapy Treatment: A Retrospective Cohort Study.
PubMed 文献 · Adv Radiat Oncol · 2020-10-14

结果显示热塑膜在系统设置纵向位移和随机设置横向位移上优于胸罩,随机设置横向平面精度更高,但两组放射性皮炎发生率无显著差异。

要点

  • 随机设置横向平面±0.5 cm和±0.1 cm精度热塑膜组均显著高于胸罩组。

核心结论

  • 热塑膜固定下垂乳房放疗的摆位重复性优于商用胸罩。

临床怎么用

  • 对于下垂乳房乳腺癌放疗,可优先考虑热塑膜固定以改善摆位重复性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to compare thermoplastic mask with bra in terms of setup reproducibility and immobilization of pendulous breasts during radiation therapy (RT). METHODS AND MATERIALS: Forty-two female patients with breast cancer treated with either intensity modulated RT or 3-dimensional conformal RT were retrospectively reviewed. Of these, 21 benefited from thermoplastic mask immobilization and 21 used a bra. Setup accuracy was evaluated using consecutive cone beam computed tomography/electronic portal imaging device sessions over the first 3 days before treatment (systematic setting), followed by weekly cone beam computed tomography/electronic portal imaging device (random settings), and compared with the reference image to calculate the corresponding translational shift (setup error) in the 3 planes. Average absolute shift values in both systematic and random settings were compared between the 2 groups. Accuracy was analyzed by comparing the percentage of pooled settings within ±0.05 and ±0.1 cm of the reference image. RESULTS: Compared with a bra, use of the mask was associated with a smaller longitudinal shift in systematic settings (difference in mean: 0.27 cm; P = .027; Mann-Whitney U test) and a lesser lateral shift in random setting (difference in mean: 0.19 cm; P = .005; Mann-Whitney U test). In the pooled systematic settings, the mask performed relatively better than the bra in the lateral and longitudinal planes, with no statistical significance. In pooled random settings, mask showed greater accuracy than bra in the lateral plane with 86.0% versus 58.9% accuracy at ±0.5 cm (P < .001) and 48.8% versus 21.7% accuracy at ±0.1 cm (P < .001), respectively. There was no significant difference in the incidence of radiodermatitis between the 2 groups. However, a hypofractionation regimen was associated with a lower incidence of radiodermatitis, and the severity of skin reactions was positively correlated with treatment dose (unstandardized regression coefficient: B = .001; correlation coefficient: r = .571; P < .001). CONCLUSIONS: Masks provide superior reproducibility compared with commercially available bras.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Mulla Z, Iskanderani O, Weber A, et al. Comparing Accuracy of Thermoplastic Mask versus Commercial Bra for the Immobilization of Pendulous Breast During Radiation Therapy Treatment: A Retrospective Cohort Study. Adv Radiat Oncol. 2020. PMID: 33665487. doi:10.1016/j.adro.2020.09.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。