乳腺癌区域淋巴结VMAT放疗中自主呼吸屏气与ABC屏气的对比
本研究纳入需行全区域淋巴结容积旋转调强放疗(VMAT)的乳腺癌患者,随机交叉比较自主深呼吸屏气(vDIBH)与主动呼吸协调器辅助屏气(ABC_DIBH)的摆位重复性,含蜡模与否。16例患者均完成两种技术治疗,分次内与分次间重复性差异均无统计学意义,提示vDIBH联合VMAT可行且重复性与ABC_DIBH相当。
要点
- vDIBH与ABC_DIBH在VMAT乳腺癌区域淋巴结放疗中摆位重复性无显著差异
- 两种技术分次内胸壁与膈肌位置重复性相当
- vDIBH联合VMAT含或不含蜡模均可行
核心结论
- 在乳腺癌全区域淋巴结VMAT放疗中,简易自主屏气技术可行,重复性与ABC辅助屏气相当。
研究设计与样本
- 单中心随机交叉研究,16例需行全区域淋巴结VMAT(含或不含蜡模)屏气放疗的乳腺癌患者,随机分配前7次用一技术、后8次用另一技术,每日CBCT配准。
- 16例中9例使用蜡模、7例未使用,均完成两种技术治疗。
主要发现
- CBCT推算的系统误差∑:ABC_DIBH为2.1-6.4 mm,vDIBH为2.1-4.9 mm;随机误差α:ABC_DIBH为1.7-2.6 mm,vDIBH为2.2-2.7 mm。
- 每日胸壁平均位移:ABC_DIBH为0.0-1.5 mm,vDIBH为-0.1-1.6 mm,差异均无统计学意义。
- 连续屏气间胸壁与膈肌位置中位差异分别为1.0 mm和0.8 mm,无统计学意义,提示分次内重复性相当。
临床怎么用
- 在乳腺癌区域淋巴结VMAT屏气放疗中,可考虑采用简易自主屏气替代ABC辅助屏气以简化流程。
局限性
- 样本量仅16例,为单中心研究,结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Deep-inspiration breath-hold (DIBH) reduces radiation dose to the heart in patients undergoing locoregional breast radiotherapy. In the context of tangential irradiation of the breast/ chest wall, a voluntary breath hold (vDIBH) technique has been shown to be as reproducible as a machine-assisted breath hold technique using the active breathing co-ordinator (ABC™, Elekta, Crawley, UK, ABC_DIBH). This study compares set-up reproducibility for vDIBH versus ABC_DIBH in patients undergoing volumetric-modulated arc radiotherapy (VMAT) for breast cancer, both with and without wax bolus. METHOD: Patients with breast cancer requiring pan regional lymph node VMAT +/- wax bolus in breath-hold were CT scanned in vDIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1-7 and the other for fractions 8-15. Daily cone beam computed tomography (CBCT) was performed and registered to planning-CT using bony anatomy. Within-patient comparisons of mean daily chest wall position were made using a paired t-test. Population, systematic (∑) and random errors (α) were estimated. Intrafraction reproducibility was assessed by comparing chest wall position and diaphragm movement between consecutive breath holds on CBCT. RESULTS: 16 patients were recruited. All completed treatment with both techniques (9 patients with wax bolus, 7 patients without). CBCT derived ∑ were 2.1-6.4 mm (ABC_DIBH) and 2.1-4.9 mm (vDIBH), α were 1.7-2.6 mm (ABC_DIBH) and 2.2-2.7 mm (vDIBH) and mean daily chest wall displacements (MD) were 0.0-1.5 mm (ABC_DIBH) and -0.1-1.6 vDIBH (all p non-significant). Chest wall and diaphragm position was equivalent between consecutive breath holds in ABC and vDIBH (median difference 1.0 mm and 0.8 mm respectively, non p significant) demonstrating equivalent intrafraction reproducibility. CONCLUSION: This study demonstrates that a simple voluntary breath hold technique is feasible in combination with VMAT (+/- bolus) and is as reproducible as ABC_DIBH with VMAT for the irradiation of the breast and axillary and IMC lymph nodes in breast cancer patients.
引用
- Ranger A, Dunlop A, Grimwood A, et al. Voluntary versus ABC breath-hold in the context of VMAT for breast and locoregional lymph node radiotherapy including the internal mammary chain. Clin Transl Radiat Oncol. 2021. PMID: 33681483. doi:10.1016/j.ctro.2021.02.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。