基于方差分量分析估算深吸气屏气乳腺癌放疗计划靶区合适外扩边界
本研究纳入25例接受深吸气屏气下全乳照射的左侧乳腺癌患者,利用电影电子射野影像装置(cine EPID)监测胸壁位移并分析误差,通过方差分量分析估算计划靶区(PTV)外扩边界。结果显示患者间、分次间和分次内标准差分别为0.82 mm、1.19 mm和1.63 mm,计算所得PTV外扩边界为3.59 mm。
要点
- 深吸气屏气下左侧乳腺癌放疗的总体平均误差为0.30 mm(95%CI:-0.05–0.65)。
- 分次内标准差(1.63 mm)大于分次间(1.19 mm)和患者间(0.82 mm)。
- 基于方差分量分析估算的PTV外扩边界为3.59 mm。
核心结论
- 深吸气屏气乳腺癌放疗中利用EPID图像监测误差,方差分量分析估算的合适PTV外扩边界为3.59 mm。
研究设计与样本
- 本研究纳入25例连续接受深吸气屏气下全乳照射的左侧乳腺癌患者,使用RPM系统监测腹部前后运动,并以cine EPID评估胸壁位移。
- 共分析309,609帧cine EPID图像,采用Canny滤波器检测胸壁边缘,计算患者间、分次间和分次内标准差,通过方差分量分析估算PTV外扩边界。
主要发现
- 患者中位年龄55岁(范围35–79岁),平均照射时间为20.4 ± 1.7秒。
- 腹部前后运动为1.36 ± 0.94 mm(范围0.14–5.28 mm)。
- 总体平均误差为0.30 mm(95%CI:-0.05–0.65)。
- 患者间、分次间和分次内标准差分别为0.82 mm、1.19 mm和1.63 mm。
- 计算所得PTV外扩边界为3.59 mm。
临床怎么用
- 对于深吸气屏气下左侧乳腺癌全乳照射,可参考本研究估算的3.59 mm PTV外扩边界,并结合本中心实际误差数据个体化调整。
局限性
- 本研究样本量较小(25例),且仅针对左侧乳腺癌全乳照射深吸气屏气技术,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study aimed to quantify errors by using a cine electronic portal imaging device (cine EPID) during deep inspiration breath-hold (DIBH) for left-sided breast cancer and to estimate the planning target volume (PTV) by variance component analysis. METHODS: This study included 25 consecutive left-sided breast cancer patients treated with whole-breast irradiation (WBI) using DIBH. Breath-holding was performed while monitoring abdominal anterior-posterior (AP) motion using the Real-time Position Management (RPM) system. Cine EPID was used to evaluate the chest wall displacements in patients. Cine EPID images of the patients (309,609 frames) were analyzed to detect the edges of the chest wall using a Canny filter. The errors that occurred during DIBH included differences between the chest wall position detected by digitally reconstructed radiographs and that of all cine EPID images. The inter-patient, inter-fraction, and intra-fractional standard deviations (SDs) in the DIBH were calculated, and the PTV margin was estimated by variance component analysis. RESULTS: The median patient age was 55 (35-79) years, and the mean irradiation time was 20.4 ± 1.7 s. The abdominal AP motion was 1.36 ± 0.94 (0.14-5.28) mm. The overall mean of the errors was 0.30 mm (95% confidence interval: - 0.05-0.65). The inter-patient, inter-fraction, and intra-fractional SDs in the DIBH were 0.82 mm, 1.19 mm, and 1.63 mm, respectively, and the PTV margin was calculated as 3.59 mm. CONCLUSIONS: Errors during DIBH for breast radiotherapy were monitored using EPID images and appropriate PTV margins were estimated by variance component analysis.
引用
- Ono Y, Yoshimura M, Ono T, et al. Appropriate margin for planning target volume for breast radiotherapy during deep inspiration breath-hold by variance component analysis. Radiat Oncol. 2021. PMID: 33676532. doi:10.1186/s13014-021-01777-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。