文献速递头颈部肿瘤放疗放疗物理与技术

头颈癌自动放疗计划系统的临床可接受性

Clinical Acceptability of Automated Radiation Treatment Planning for Head and Neck Cancer Using the Radiation Planning Assistant.
PubMed 文献 · Pract Radiat Oncol · 2021-02-25

本研究纳入50例在三级中心接受治疗的头颈癌患者,用全自动放疗计划系统Radiation Planning Assistant基于原批准轮廓生成自动计划,并与临床已批准并实施的手工计划比较。常用DVH指标显示两者覆盖与危及器官约束相似;

要点

  • 自动计划与临床计划在DVH覆盖和危及器官约束指标上非常相似。
  • 盲法评审中88%自动计划、78%临床计划可原样使用。
  • 72%评审者认为自动计划或两者之一更可取,0%认为两者均不可用。

核心结论

  • 自动放疗计划可生成一致、临床可接受且满足DVH标准、经医生评审认可的头颈癌治疗计划。

研究设计与样本

  • 研究队列为50例在三级中心由专门头颈癌团队治疗的患者,使用Radiation Planning Assistant基于原批准轮廓生成自动计划,并与临床已批准并实施的手工计划比较。
  • 采用常用DVH标准比较自动计划与临床计划质量。

主要发现

  • 自动计划与临床计划在覆盖和关键结构约束的DVH指标上非常相似。
  • 医生评审认为临床计划与自动计划均可接受;总体78%的临床计划和88%的自动计划可原样使用(无需任何修改)。
  • 在被要求选择更倾向批准的计划时,27%的医生评审选择临床计划,47%选择自动计划,25%认为两者等效,0%认为两者均不可取。
  • 总体72%的医生评审认为自动计划或临床计划与自动计划任一者更可取。

关键数值与推荐

  • 78%的临床计划被评审认为可原样使用(无需任何修改)。
  • 88%的自动计划被评审认为可原样使用(无需任何修改)。
  • 选择偏好:27%选临床计划,47%选自动计划,25%认为两者等效,0%认为两者均不可取。

临床怎么用

  • 对于头颈癌放疗,自动计划系统可基于已批准轮廓生成满足常用DVH标准且经医生盲法评审可接受的计划,可作为提高计划质量与效率的选项。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation treatment planning for head and neck cancer is a complex process with much variability; automated treatment planning is a promising option to improve plan quality and efficiency. This study compared radiation plans generated from a fully automated radiation treatment planning system to plans generated manually that had been clinically approved and delivered. METHODS AND MATERIALS: The study cohort consisted of 50 patients treated by a specialized head and neck cancer team at a tertiary care center. An automated radiation treatment planning system, the Radiation Planning Assistant, was used to create autoplans for all patients using their original, approved contours. Common dose-volume histogram (DVH) criteria were used to compare the quality of autoplans to the clinical plans. Fourteen radiation oncologists, each from a different institution, then reviewed and compared the autoplans and clinical plans in a blinded fashion. RESULTS: Autoplans and clinical plans were very similar with regard to DVH metrics for coverage and critical structure constraints. Physician reviewers found both the clinical plans and autoplans acceptable for use; overall, 78% of the clinical plans and 88% of the autoplans were found to be usable as is (without any edits). When asked to choose which plan would be preferred for approval, 27% of physician reviewers selected the clinical plan, 47% selected the autoplan, 25% said both were equivalent, and 0% said neither. Hence, overall, 72% of physician reviewers believed the autoplan or either the clinical or autoplan was preferable. CONCLUSIONS: Automated radiation treatment planning creates consistent, clinically acceptable treatment plans that meet DVH criteria and are found to be appropriate on physician review.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Olanrewaju A, Court LE, Zhang L, et al. Clinical Acceptability of Automated Radiation Treatment Planning for Head and Neck Cancer Using the Radiation Planning Assistant. Pract Radiat Oncol. 2021. PMID: 33640315. doi:10.1016/j.prro.2020.12.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。