CT引导优化局部晚期宫颈癌Utrecht施源器插植针插入研究

Computed Tomography-Guided Optimization of Needle Insertion for Combined Intracavitary/Interstitial Brachytherapy With Utrecht Applicator in Locally Advanced Cervical Cancer.
PubMed 文献 · Pract Radiat Oncol · 2021-02-05

该研究纳入24例接受组织间近距离放疗的局部晚期宫颈癌患者,通过施源器插入后无针CT和有针CT两次扫描,评估CT引导优化插植针插入的临床可行性与增益价值及针偏移情况。结果显示该方法可行,减少了未装载针插入和并发症,针贡献总驻留时间平均37.2%±19.2%,68%的针发生偏移但无需重新插入。

要点

  • CT引导自适应IS-ICBT可行,减少未装载针插入和并发症。
  • 针贡献总驻留时间平均37.2%±19.2%,使用效率提高。
  • 68%的针发生偏移(平均2.0±2.3 mm),但无需重新插入。

核心结论

  • CT引导的自适应IS-ICBT应用可行,减少了未装载针插入或并发症,并提高了针贡献总驻留时间的效率。
  • 针偏移频繁发生但采用所提方法无需重新插入。

研究设计与样本

  • 纳入24例接受组织间近距离放疗的患者,每例进行两次CT扫描:施源器插入后无针(CTpreneedle)和插针后(CTpostneedle)。
  • 基于CTpreneedle确定最佳针位置和插入长度,CTpostneedle用于IS-ICBT计划,以针道轴线为参考评估针偏移。

主要发现

  • 共在93个近距离放疗分次中的76个分次插入266根组织间针,针数在患者内和患者间差异大。
  • 根据CTpreneedle结果,第1、2、3、4分次分别有9、4、2、2例患者避免插针,未装载针频率为4%。
  • 针贡献总驻留时间平均37.2%±19.2%。
  • 68%的针发生偏移(平均2.0±2.3 mm),主要向后方向,且见于插入长度较大的针。
  • 无患者需要重新插针,除1例拔针后轻微阴道出血外无插针相关并发症。

临床怎么用

  • 在局部晚期宫颈癌的IS-ICBT中,可考虑使用CT引导优化插植针插入位置和长度,以减少未装载针和并发症。
  • 针偏移常见但可能无需重新插入,需结合所提方法评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: There are no international guidelines for optimal needle insertion during interstitial intracavitary brachytherapy (IS-ICBT) for cervical cancer. We aimed to investigate the clinical feasibility and added value of computed tomography (CT) guidance to optimize needle insertion in IS-ICBT using the Utrecht applicator and to evaluate needle shifts. METHODS AND MATERIALS: We enrolled 24 patients who were treated with interstitial-brachytherapy. Two CT scans each were performed for every patient: (1) after applicator insertion without needles (CTpreneedle) and (2) after needle insertion (CTpostneedle). In addition to magnetic resonance imaging after external-beam radiation therapy, CTpreneedle was used to determine optimal needle locations and insertion lengths based on applicator and organs at risk positioning on the day of treatment; CTpostneedle was used for IS-ICBT planning. The needle-channel axis was used as a reference to determine needle-shift evolution. RESULTS: A total of 266 interstitial needles were inserted in 76 of 93 BT fractions with high intra- and interpatient variations in the number of inserted needles. Based on CTpreneedle findings, needle insertion was avoided in 9, 4, 2, and 2 patients at the first, second, third, and fourth fractions, respectively. The unloaded needle frequency was 4%. Average needle contribution to total dwell time was 37.2% ± 19.2%. Shifting was observed in 68% of the needles (mean shift 2.0 ± 2.3 mm), mostly in the posterior direction, and in needles with a larger insertion length. Needle reinsertion was not needed in any patient. No complication due to needle insertion was observed, except for minor vaginal bleeding in 1 patient after needle removal. CONCLUSIONS: The adaptive CT-guided IS-ICBT application was feasible and resulted in fewer unloaded needle insertions or complications and more efficient use with higher needle contribution to the treatment. Needle shift was frequent but did not require needle reinsertion with the proposed method.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。