放射治疗师在MRI引导直线加速器上为前列腺癌实施每日在线轮廓适应的评估
本研究评估放射治疗师(RTT)在MR-Linac上为30例低中危前列腺癌患者(5次×7.25 Gy)每日在线生成临床靶区(CTV)轮廓的可行性。结果显示RTT轮廓与医师适配轮廓的观察者间Dice相似系数中位数达0.99–1.00,94.2%的分次轮廓临床可接受,在线轮廓适应平均耗时12.6分钟。
要点
- RTT每日在线轮廓适应平均耗时12.6分钟,临床可行。
- RTT与医师轮廓的观察者间DSC中位数达0.99–1.00。
核心结论
- 放射治疗师每日在线轮廓适应用于MR-Linac前列腺癌治疗在临床上是可行的。
研究设计与样本
- 研究纳入30例低中危前列腺癌患者,接受5次×7.25 Gy治疗,由RTT在线生成CTV轮廓,两名医师观察者判断并按需适配。
- 计算RTT与两名观察者及观察者之间的分次间相对体积差异和观察者间Dice相似系数(DSC),并由第三观察者判断RTT轮廓的临床可接受性。
主要发现
- 在线轮廓适应时间均值(SD)为12.6(±3.8)分钟。
- 总体相对体积差异中位数(IQR)为9.3%(4.4–13.0)。
- 观察者的适配主要发生在前列腺尖部和底部。
- RTT与观察者1、RTT与观察者2、观察者1与2的观察者间DSC中位数(IQR)分别为0.99(0.98–1.00)、1.00(0.98–1.00)、1.00(0.99–1.00)。
- 轮廓在113个分次(94.2%)中临床可接受;剂量体积直方图(DVH)分析显示7个离群值中1个存在显著CTV剂量不足。
关键数值与推荐
- 观察者间DSC中位数:RTT与观察者1为0.99,RTT与观察者2为1.00,观察者1与2为1.00。
临床怎么用
- 经培训的RTT可承担MR-Linac前列腺癌每日在线轮廓适应,但需医师判断并按需适配,尤其关注尖部和底部。
- 对离群轮廓应进行DVH核查以发现潜在CTV剂量不足。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Magnetic resonance (MR)-guided linear accelerator (MR-Linac) systems have changed radiotherapy workflows. The addition of daily online contour adaptation allows for higher precision treatment, but also increases the workload of those involved. We train radiation therapists (RTTs) to perform daily online contour adaptation for MR-Linac treatment of prostate cancer (PCa) patients. The purpose of this study was to evaluate these prostate contours by performing an interfraction and interobserver analysis. MATERIALS AND METHODS: Clinical target volume (CTV) contours generated online by RTTs from 30 low-intermediate risk PCa patients, treated with 5x7.25 Gy, were used. Two physicians (Observers) judged the RTTs contours and performed adaptations when necessary. Interfraction relative volume differences between the first and the subsequent fractions were calculated for the RTTs, Observer 1, and Observer 2. Additionally, interobserver dice's similarity coefficient (DSC) for fraction 2-5 was calculated with the RTTs- and physician-adapted contours. Clinical acceptability of the RTTs contours was judged by a third observer. RESULTS: Mean (SD) online contour adaptation time was 12.6 (±3.8) minutes and overall median (interquartile range [IQR]) relative volume difference was 9.3% (4.4-13.0). Adaptations by the observers were mostly performed at the apex and base of the prostate. Median (IQR) interobserver DSC between RTTs and Observer 1, RTTs and Observer 2, and Observer 1 and 2 was 0.99 (0.98-1.00), 1.00 (0.98-1.00), and 1.00 (0.99-1.00), respectively. Contours were acceptable for clinical use in 113 (94.2%) fractions. Dose-volume histogram (DVH) analysis showed significant CTV underdosage for one of the seven identified outliers. CONCLUSION: Daily online contour adaptation by RTTs is clinically feasible for MR-Linac treatment of PCa.
引用
- Willigenburg T, de Muinck Keizer DM, Peters M, et al. Evaluation of daily online contour adaptation by radiation therapists for prostate cancer treatment on an MRI-guided linear accelerator. Clin Transl Radiat Oncol. 2021. PMID: 33532630. doi:10.1016/j.ctro.2021.01.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。