文献速递乳腺癌放疗放疗物理与技术

深度学习自动勾画保乳术后乳腺癌靶区与危及器官的临床可行性

Clinical feasibility of deep learning-based auto-segmentation of target volumes and organs-at-risk in breast cancer patients after breast-conserving surgery.
PubMed 文献 · Radiat Oncol · 2021-02-25

该研究在111例保乳术后乳腺癌患者的计划CT上,比较深度学习自动勾画与人工勾画的靶区(双侧乳腺及区域淋巴结)和危及器官。结果显示危及器官平均DSC均高于0.80,靶区平均DSC均高于0.70,主观评分中位至少8分,剂量学参数差异极小,表明自动勾画在乳腺癌放疗计划中具有可行性。

要点

  • 危及器官自动勾画与人工勾画平均DSC均高于0.80,靶区平均DSC均高于0.70。
  • 来自10家机构的两组主观评分对全部靶区和危及器官可接受,中位至少8分(范围0-10)。
  • 自动与人工勾画的剂量学参数差异极小,但自动勾画不能替代放疗肿瘤医生。

核心结论

  • 深度学习自动勾画在乳腺癌放疗计划中具有可行性,是有潜力辅助放疗肿瘤医生的工具,但不能替代放疗肿瘤医生。

研究设计与样本

  • 在111例接受保乳手术的乳腺癌患者的计划CT扫描上手动勾画双侧乳腺和区域淋巴结的临床靶区(CTV)以及危及器官(OARs),包括心脏、肺、食管、脊髓和甲状腺。
  • 采用两阶段卷积神经网络算法进行自动勾画,并使用Dice相似系数(DSC)和95% Hausdorff距离等定量指标以及来自10家机构的两组面板进行定性评分分析。
  • 评估了观察者间变异性和勾画时间,并使用另一组患者数据分析了剂量体积直方图和剂量学参数。

主要发现

  • 自动勾画与手动勾画在危及器官上的相关性可接受,所有危及器官的平均DSC高于0.80。
  • 所有乳腺和区域淋巴结CTV的平均DSC高于0.70。
  • 定性主观评分显示所有CTV和OARs的结果可接受,对于手动与自动勾画轮廓之间的差异以及自动勾画在临床实践中辅助医生的程度,中位评分至少为8分(可能范围:0-10)。
  • 自动勾画与手动勾画之间的剂量学参数差异极小。

关键数值与推荐

  • 危及器官自动勾画与手动勾画的平均DSC均高于0.80。
  • 乳腺和区域淋巴结CTV自动勾画与手动勾画的平均DSC均高于0.70。
  • 定性主观评分中位至少8分(可能范围:0-10),评分项为手动与自动勾画轮廓差异及自动勾画辅助临床实践的程度。

临床怎么用

  • 深度学习自动勾画可作为辅助放疗肿瘤医生进行乳腺癌放疗计划的工具,但不应替代放疗肿瘤医生。
  • 自动勾画与手动勾画的剂量学参数差异极小,支持其在临床计划流程中的潜在应用。

局限性

  • 研究为回顾性注册,摘要未报告其他局限性信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In breast cancer patients receiving radiotherapy (RT), accurate target delineation and reduction of radiation doses to the nearby normal organs is important. However, manual clinical target volume (CTV) and organs-at-risk (OARs) segmentation for treatment planning increases physicians' workload and inter-physician variability considerably. In this study, we evaluated the potential benefits of deep learning-based auto-segmented contours by comparing them to manually delineated contours for breast cancer patients. METHODS: CTVs for bilateral breasts, regional lymph nodes, and OARs (including the heart, lungs, esophagus, spinal cord, and thyroid) were manually delineated on planning computed tomography scans of 111 breast cancer patients who received breast-conserving surgery. Subsequently, a two-stage convolutional neural network algorithm was used. Quantitative metrics, including the Dice similarity coefficient (DSC) and 95% Hausdorff distance, and qualitative scoring by two panels from 10 institutions were used for analysis. Inter-observer variability and delineation time were assessed; furthermore, dose-volume histograms and dosimetric parameters were also analyzed using another set of patient data. RESULTS: The correlation between the auto-segmented and manual contours was acceptable for OARs, with a mean DSC higher than 0.80 for all OARs. In addition, the CTVs showed favorable results, with mean DSCs higher than 0.70 for all breast and regional lymph node CTVs. Furthermore, qualitative subjective scoring showed that the results were acceptable for all CTVs and OARs, with a median score of at least 8 (possible range: 0-10) for (1) the differences between manual and auto-segmented contours and (2) the extent to which auto-segmentation would assist physicians in clinical practice. The differences in dosimetric parameters between the auto-segmented and manual contours were minimal. CONCLUSIONS: The feasibility of deep learning-based auto-segmentation in breast RT planning was demonstrated. Although deep learning-based auto-segmentation cannot be a substitute for radiation oncologists, it is a useful tool with excellent potential in assisting radiation oncologists in the future. Trial registration Retrospectively registered.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Chung SY, Chang JS, Choi MS, et al. Clinical feasibility of deep learning-based auto-segmentation of target volumes and organs-at-risk in breast cancer patients after breast-conserving surgery. Radiat Oncol. 2021. PMID: 33632248. doi:10.1186/s13014-021-01771-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。