文献速递乳腺癌放疗放疗物理与技术

临床相关剂量部分心脏照射后小鼠心血管损伤特征

Characterization of cardiovascular injury in mice following partial-heart irradiation with clinically relevant dose and fractionation.
PubMed 文献 · Radiother Oncol · 2021-02-03

该研究建立模拟左乳腺癌/胸壁放疗剂量、分割与射束布置的小鼠模型,对C57BL/6J与ApoE-/-小鼠行2 Gy×25次部分心脏照射,无创影像未见灌注或心功能显著下降,但ApoE-/-小鼠12个月时PV loop分析显示心输出量及dV/dtmax、dV/dt min显著降低。

要点

  • 2 Gy×25次部分心脏照射后18个月内,C57BL/6J小鼠SPECT与超声心动图未见显著变化。
  • ApoE-/-小鼠照射后12个月PV loop分析显示心输出量、dV/dtmax与dV/dt min显著下降。
  • 无创影像(超声、SPECT、DE-CT)未检出放疗相关心肌灌注或心功能下降,PV loop或可检测细微变化。

核心结论

  • 临床相关剂量部分心脏照射后,无创影像未见心肌灌注下降或心功能障碍证据,但ApoE-/-小鼠PV loop分析显示细微但显著的心功能变化。

研究设计与样本

  • 女性野生型C57BL/6J与动脉粥样硬化易感ApoE-/-小鼠(C57BL/6J背景)予常规饲料,经对穿切线束行左胸壁2 Gy×25次部分心脏照射。
  • C57BL/6J小鼠用SPECT与超声心动图评估心肌灌注与心功能,ApoE-/-小鼠另用双能microCT与PV loop分析评估钙化斑块与心功能。
  • 心肌纤维化用组织病理学检查。

主要发现

  • 与未照射对照相比,C57BL/6J小鼠照射后18个月内SPECT与超声心动图未见显著变化,但心肌纤维化轻度增加。
  • ApoE-/-小鼠照射后SPECT、DE-CT与超声心动图未见显著变化。
  • ApoE-/-小鼠照射后12个月PV loop分析显示负荷依赖性收缩与舒张功能指标显著下降,包括心输出量、dV/dtmax与dV/dt min。

临床怎么用

  • 对接受左乳腺癌或胸壁放疗且伴动脉粥样硬化风险的患者,常规无创影像可能低估细微心功能损伤。
  • 临床前放射诱导心脏病研究若预期心功能细微变化,可考虑采用PV loop分析作为补充评估手段。

局限性

  • 研究为小鼠模型,结果外推至临床人群需谨慎。
  • 无创影像未检出显著变化,细微心功能改变仅见于ApoE-/-小鼠的侵入性PV loop分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Late cardiac toxicity is a major side effect of radiation therapy (RT) for breast cancer. We developed and characterized a mouse model of radiation-induced heart disease that mimics the dose, fractionation, and beam arrangement of left breast and chest wall RT. MATERIAL AND METHODS: Female wild-type (C57BL6/J) and atherosclerosis-prone apolipoprotein E-deficient (ApoE-/-) mice (on a C57BL/6J background) on regular chow were treated with 2 Gy × 25 fractions of partial-heart irradiation via opposed tangential beams to the left chest wall. The changes in myocardial perfusion and cardiac function of C57BL/6J mice were examined by single-photon emission computed tomography (SPECT) and echocardiography, respectively. In addition to SPECT and echocardiography, the formation of calcified plaques and changes in cardiac function of ApoE-/- mice were examined by dual-energy microCT (DE-CT) and pressure-volume (PV) loop analysis, respectively. The development of myocardial fibrosis was examined by histopathology. RESULTS: Compared to unirradiated controls, irradiated C57BL/6J mice showed no significant changes by SPECT or echocardiography up to 18 months after 2 Gy × 25 partial-heart irradiation even though irradiated mice exhibited a modest increase in myocardial fibrosis. For ApoE-/- mice, 2 Gy × 25 partial-heart irradiation did not cause significant changes by SPECT, DE-CT, or echocardiography. However, PV loop analysis revealed a significant decrease in load-dependent systolic and diastolic function measures including cardiac output, dV/dtmax and dV/dt min 12 months after RT. CONCLUSIONS: Following clinically relevant doses of partial-heart irradiation in C57BL/6J and ApoE-/- mice, assessment with noninvasive imaging modalities such as echocardiography, SPECT, and DE-CT yielded no evidence of decreased myocardial perfusion and cardiac dysfunction related to RT. However, invasive hemodynamic assessment with PV loop analysis indicated subtle, but significant, changes in cardiac function of irradiated ApoE-/- mice. PV loop analysis may be useful for future preclinical studies of radiation-induced heart disease, especially if subtle changes in cardiac function are expected.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Lee CL, Lee JW, Daniel AR, et al. Characterization of cardiovascular injury in mice following partial-heart irradiation with clinically relevant dose and fractionation. Radiother Oncol. 2021. PMID: 33545252. doi:10.1016/j.radonc.2021.01.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。