文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

宫颈癌腹主动脉旁淋巴结预防性放疗解剖图谱的更新与优化

Updating and Optimizing Anatomic Atlases for Elective Radiation of Para-Aortic Lymph Nodes in Cervical Cancer.
PubMed 文献 · Pract Radiat Oncol · 2021-01-06

本研究基于47例宫颈癌患者治疗前PET/CT显示的176枚PET阳性腹主动脉旁淋巴结(PAN),更新PAN解剖图谱并评估两套已有CTV勾画指南(CTV-T与CTV-K)的覆盖情况。结果显示CTV-T淋巴结中心覆盖率为97.6%,显著优于CTV-K的85.0%(P<.001)。作者建议融合CTV-T与CTV-K以优化大血管前方淋巴结覆盖。

要点

  • 基于176枚PET阳性PAN更新宫颈癌预防性放疗解剖图谱。
  • CTV-T淋巴结中心覆盖率97.6%,显著优于CTV-K的85.0%。
  • 建议融合CTV-T与CTV-K以覆盖大血管前方淋巴结。

核心结论

  • 基于47例患者176枚PET阳性PAN的数据,CTV-T对后侧LPA及腔静脉后区域的覆盖显著优于CTV-K。
  • 建议融合CTV-T与CTV-K以优化对大血管前方映射淋巴结的覆盖。

研究设计与样本

  • 回顾性分析47例FIGO IB至IVA期宫颈癌患者治疗前PET/CT显示的176枚PET阳性PAN。
  • 将PAN分为左侧腹主动脉旁(LPA)、主腔静脉间(AC)和右侧腔静脉旁(RPC)三类。
  • 按已发表的Takiar指南(CTV-T)和Keenan指南(CTV-K)勾画PAN临床靶区并评估淋巴结体积覆盖。

主要发现

  • 176枚PAN中LPA 94枚(54%)、AC 71枚(40%)、RPC 11枚(6%)。
  • CTV-T淋巴结中心覆盖率为97.6%,CTV-K为85.0%(P<.001)。
  • LPA淋巴结中心覆盖CTV-K为79枚(84.0%)、CTV-T为93枚(99.0%)(P=.001)。
  • AC淋巴结中心覆盖CTV-K为64枚(90.1%)、CTV-T为68枚(95.8%)(P=.221)。
  • RPC淋巴结中心覆盖CTV-K为5枚(45.5%)、CTV-T为9枚(81.8%)(P=.134)。

关键数值与推荐

  • CTV-T对淋巴结中心覆盖率为97.6%,CTV-K为85.0%(P<.001)。
  • CTV-K因主动脉前方10 mm外扩而覆盖了CTV-T未覆盖的主动脉与下腔静脉前方淋巴结中心。

临床怎么用

  • 宫颈癌预防性腹主动脉旁淋巴结放疗可优先参考CTV-T以提高后侧LPA及腔静脉后区域覆盖。
  • 对大血管前方淋巴结,可考虑融合CTV-T与CTV-K的勾画范围以优化覆盖。

局限性

  • 图谱基于单中心47例患者的PET阳性淋巴结数据,样本量有限。
  • 覆盖评估基于淋巴结中心点而非完整淋巴结体积。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Previous studies have proposed 2 different contouring guidelines for the prophylactic radiation of para-aortic lymph nodes (PANs) for locally advanced cervical cancer. Because PAN-mapping atlases in current literature are limited to small patient samples and nodal populations, we updated the PAN atlas with a large data set of positron emission tomography (PET)-positive PANs on PET/computed tomography (CT) from patients with cervical cancer. METHODS AND MATERIALS: We identified 176 PET-positive PANs on pretreatment PET/CT of 47 patients with diagnosed International Federation of Gynecology and Obstetrics stage IB to IVA cervical cancer. PANs were classified as left-lateral para-aortic (LPA), aortocaval (AC), or right paracaval (RPC). PAN clinical target volume (CTV) contours were drawn for all patients based on previously published guidelines by Takiar (CTV-T) and Keenan (CTV-K) and nodal volumetric coverage was assessed. RESULTS: We identified 94 LPA nodes (54%), 71 AC nodes (40%), and 11 (6%) RPC nodes. CTV-T had improved nodal center coverage of 97.6% compared with 85.0% for CTV-K (P < .001). Nodal center coverage for CTV-K and CTV-T (with corresponding PAN) were 79 (84.0%) and 93 (99.0%) LPA nodes (P = .001), 64 (90.1%) and 68 (95.8%) AC nodes (P = .221), and 5 (45.5%) and 9 (81.8%) RPC nodes (P = .134), respectively. Additionally, our updated PAN atlas identified nodal centers anterior to the aorta and inferior vena cava that are not covered by CTV-T but covered by CTV-K due to the 10 mm anterior aortic expansion of CTV-K. CONCLUSIONS: We have updated the PAN anatomic map of 176 PET-positive nodes from 47 patients and demonstrated that CTV-T has significantly better PAN coverage over CTV-K for posterior LPA and retrocaval regions for our data set. Additionally, we suggest a modification that includes a blend of CTV-T and CTV-K to provide optimal coverage for the mapped nodes anterior to the great vessels in our data set.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. D'Cunha P, Pinho DF, Nwachukwu C, et al. Updating and Optimizing Anatomic Atlases for Elective Radiation of Para-Aortic Lymph Nodes in Cervical Cancer. Pract Radiat Oncol. 2021. PMID: 33421621. doi:10.1016/j.prro.2020.12.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。