基于锥形束CT的每日自适应计划与规定充盈方案在新辅助胃癌放疗中的比较

Cone Beam CT-Based Daily Adaptive Planning or Defined-Filling Protocol for Neoadjuvant Gastric Cancer Radiation Therapy: A Comparison.
PubMed 文献 · Adv Radiat Oncol · 2020-10-13

本研究在离线模拟的新辅助胃癌放疗中,比较基于锥形束CT(CBCT)的自适应放疗与规定充盈方案在可行性和每日可重复剂量体积指标方面的差异。结果显示自适应计划可改善GTV覆盖并降低心脏、肝脏和右肾平均剂量,且差异均有统计学意义。

要点

  • 自适应计划使GTV的D95覆盖较非自适应计划提高5.26%。
  • 自适应计划中心脏、肝脏和右肾平均剂量分别降低35.74%、10.71%和29.47%。
  • 所有GTV和OARs的R-CBCT与A-CBCT比较差异均有统计学意义(P < .0001)。

核心结论

  • 基于可变形配准的自适应放疗在新辅助胃癌照射中可涵盖每日变异和器官运动,相比规定充盈方案改善了OAR保护。

研究设计与样本

  • 使用一名既往治疗患者的计划CT和25次CBCT扫描离线模拟新辅助胃癌放疗,PTV按TOPGEAR协议定义为45 Gy/1.8 Gy,并对GTV加量至50.4 Gy/2.016 Gy。
  • 患者遵循12小时禁食后照射前立即饮水200 mL的充盈方案,在每次CBCT上重新勾画OARs和PTVs,并进行PCT与CBCT的非刚性配准。
  • 共获得R-CBCT和A-CBCT各200个计划,肾脏、肝脏和心脏的剂量参数比较使用配对t检验。

主要发现

  • CBCT扫描中胃平均体积为277.32 cm3(±54.40 cm3),PCT中为519.2 cm3。
  • PTV平均剂量在CBCT扫描间差异无实际意义,平均为1.54%。
  • 自适应计划使GTV的D95覆盖较R-CBCT计划提高5.26%。
  • 自适应计划中心脏、肝脏和右肾平均剂量分别降低35.74%、10.71%和29.47%。
  • GTV和OARs的R-CBCT与A-CBCT比较在所有情况下均显著不同(P < .0001)。

关键数值与推荐

  • PTV处方剂量为45 Gy/1.8 Gy,GTV整合加量至50.4 Gy/2.016 Gy(依据TOPGEAR协议)。
  • 充盈方案为12小时禁食后照射前立即饮水200 mL(2杯水)。
  • 自适应计划使GTV的D95覆盖提高5.26%,心脏、肝脏和右肾平均剂量分别降低35.74%、10.71%和29.47%(P < .0001)。

临床怎么用

  • 在新辅助胃癌放疗中可考虑采用基于CBCT的可变形配准自适应放疗以涵盖每日变异和器官运动。
  • 自适应计划可在保持PTV平均剂量无明显差异的同时改善GTV覆盖并降低心脏、肝脏和右肾剂量。

局限性

  • 本研究为基于单一名既往治疗患者数据的离线模拟,非前瞻性临床研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to investigate, in the setting of neoadjuvant gastric irradiation with integrated boost, whether cone beam computed tomography (CBCT)-based adaptive radiation therapy compared with a defined-filling protocol would be beneficial in terms of feasibility and achieving daily reproducible dose volume indexes of the planning target volume (PTV) and organs at risk (OARs) and workflow. METHODS AND MATERIALS: Planning computed tomography (PCT) and 25 CBCT scans of a previously treated patient were used, and neoadjuvant therapy of gastric carcinoma was simulated offline. PTVs and OARs were defined per the TOPGEAR protocol (PTV: 45 Gy/1.8 Gy), and an integrated boost (gross tumor volume [GTV]: 50.4 Gy/2.016 Gy) was added. The patient followed a filling regimen consisting of 12-hour fasting followed by 200 mL of water intake (2 glasses of water) immediately before irradiation. OARs and PTVs were newly contoured on each CBCT. Nonrigid registration of PCT and CBCT scans was performed. Nonadapted plans were recalculated on each CBCT (R-CBCT). Furthermore, an adapted plan was created for the new anatomy (A-CBCT). Dose parameters and comparison of R-CBCT and A-CBCT for the kidneys, liver, and heart were analyzed using a paired t test. RESULTS: A total of 200 plans for R-CBCT and A-CBCT were obtained. Mean gastric volumes were 277.32 cm3 (±54.40 cm3) in CBCT scans and 519.2 cm3 in PCT. Mean doses to the PTV did not differ meaningfully within the CBCT scans, with an average of 1.54%. The D95 improved in GTV coverage by 5.26% compared with the R-CBCT plan. Mean heart, liver, and right kidney doses were reduced with the A-CBCT plan by 35.74%, 10.71% and 29.47%, respectively. The R- and A-CBCT comparison for GTV and OARs was significantly different in all cases (P < .0001). CONCLUSIONS: Adaptive radiation therapy through deformable registration represents an important tool in neoadjuvant gastric irradiation, encompassing daily variability and organ motion, compared with the defined-filling protocol while improving OAR sparing.