食管癌放化疗后剂量依赖性放射性心肌损伤的前瞻性心脏磁共振研究
这项前瞻性研究纳入19例预期长期生存的食管癌患者,用延迟钆增强磁共振(LGE MRI)评估纵隔放疗后心肌损伤。结果显示,左心室受照剂量超过30 Gy的区域出现剂量依赖性的信号强度改变,68%(13/19)的患者在>30 Gy区域检出LGE,提示可能需要减少受照超过30 Gy的心肌体积。
要点
- 左心室受照>30 Gy区域出现剂量依赖性LGE信号强度改变。
- 68%(13/19)患者在>30 Gy区域检出LGE。
- 或需减少心肌受照超过30 Gy的体积。
核心结论
- LGE MRI显示纵隔放疗后心肌信号强度改变与受照剂量呈剂量依赖性关系,可能需要减少受照超过30 Gy的心肌体积。
研究设计与样本
- 前瞻性研究纳入19例预期通过根治性治疗长期生存的食管癌患者,分别于治疗前(19例)、治疗后6个月(19例)和治疗后1.5年(12例)行延迟增强MRI。
- 用CT制作左心室剂量分布并计算剂量体积直方图,以受照<5 Gy区域均值归一化心肌信号强度,按0–10、10–20、20–30、30–40、40–50、50–60 Gy分区比较信号强度变化。
- 患者接受同步放化疗,中位总剂量60 Gy(50.4–66 Gy),化疗为顺铂联合5-氟尿嘧啶。
主要发现
- 基于人群的剂量-反应曲线显示,受照超过30 Gy的区域信号强度改变随剂量递增而逐渐增加。
- 治疗后6个月和1.5年,20–30 Gy区域平均相对信号强度变化分别为1.1%和-1.9%,40–50 Gy区域分别为37.5%和17.5%。
- 68%(13/19)的患者在受照超过30 Gy区域检出LGE。
临床怎么用
- 放疗计划评估时关注左心室受照超过30 Gy的体积,可能有助于减轻放射性心肌损伤。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this prospective study was to evaluate radiation-induced myocardial damage after mediastinal radiation therapy (RT) using late gadolinium-enhancement (LGE) magnetic resonance imaging (MRI). METHODS AND MATERIALS: We enrolled 19 patients with esophageal cancer who were expected to have long-term survival by definitive treatment. They underwent delayed contrast-enhanced MRI (19 patients before treatment, 19 patients 6 months after treatment, and 12 patients 1.5 years after treatment). Dose distribution of the left ventricle was made using computed tomography, and the dose volume histogram of the left ventricle was calculated. Myocardial signal intensities in individual MRIs were normalized by the mean values in regions receiving low doses (<5 Gy). Changes in the normalized signal intensities after mediastinal radiation therapy were compared among regions where irradiation doses were 0 to 10 Gy, 10 to 20 Gy, 20 to 30 Gy, 30 to 40 Gy, 40 to 50 Gy, and 50 to 60 Gy, and we investigated whether intensity change was detected in a dose-dependent manner. RESULTS: The registered patients were treated with concurrent chemoradiotherapy with a median total dose of 60 Gy (50.4-66 Gy). Chemotherapy consisting of cisplatin and 5-fluorouracil was administered. In the population-based dose-response curve, dose-dependent intensity changes progressively increased in regions receiving more than 30 Gy. The averages of relative intensity change at 6 months and 1.5 years after treatment were 1.1% and -1.9% at 20 to 30 Gy and 37.5% and 17.5% at 40 to 50 Gy, respectively. LGE in regions receiving more than 30 Gy was detected in 68% (13/19) of the patients. CONCLUSIONS: A dose-dependent relationship for myocardial signal intensity change was found by using LGE MRI. It may be necessary to reduce the volume of the myocardium receiving more than 30 Gy.
引用
- Umezawa R, Kadoya N, Ota H, et al. Dose-Dependent Radiation-Induced Myocardial Damage in Esophageal Cancer Treated With Chemoradiotherapy: A Prospective Cardiac Magnetic Resonance Imaging Study. Adv Radiat Oncol. 2020. PMID: 33305078. doi:10.1016/j.adro.2020.07.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。