文献速递头颈部肿瘤放疗放疗物理与技术

自动识别低优先级危及器官以优化放疗计划流程

An Automated Workflow to Improve Efficiency in Radiation Therapy Treatment Planning by Prioritizing Organs at Risk.
PubMed 文献 · Adv Radiat Oncol · 2020-06-25

使用未审核的自动勾画低优先级OAR优化计划,达到了与全部手动勾画OAR相同的计划目标,表明临床等效。

要点

  • 基于处方和靶区信息估算剂量,可自动识别无需手动勾画的低优先级OAR。
  • 头颈癌患者中约33%的OAR可被归为低优先级,减少手动勾画和审核负担。
  • 低优先级OAR使用自动勾画且不修改,计划质量与全部手动勾画无临床差异。

核心结论

  • 利用估算剂量分布对OAR进行优先级排序,可大幅减少手动勾画和审核需求,且不影响临床相关剂量学。

研究设计与样本

  • 研究纳入10例头颈癌患者,仅用处方和靶区信息生成初步剂量图,结合自动勾画结构加空间扩展缓冲保守估算OAR剂量指标。

主要发现

  • 使用未审核未修改的自动勾画低优先级OAR优化计划,满足所有与全部手动勾画OAR计划相同的计划目标,表明临床等效。

关键数值与推荐

  • 预估剂量指标低于临床耐受量的OAR被判定为低优先级,排除于手动勾画和/或审核之外。
  • 采用多个不同空间缓冲以应对不同的潜在勾画不确定性。

临床怎么用

  • 可基于初步剂量估算自动筛选低优先级OAR,将其自动勾画结果直接用于计划优化,减少手动勾画和审核工作量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Manual delineation (MD) of organs at risk (OAR) is time and labor intensive. Auto-delineation (AD) can reduce the need for MD, but because current algorithms are imperfect, manual review and modification is still typically used. Recognizing that many OARs are sufficiently far from important dose levels that they do not pose a realistic risk, we hypothesize that some OARs can be excluded from MD and manual review with no clinical effect. The purpose of this study was to develop a method that automatically identifies these OARs and enables more efficient workflows that incorporate AD without degrading clinical quality. METHODS AND MATERIALS: Preliminary dose map estimates were generated for n = 10 patients with head and neck cancers using only prescription and target-volume information. Conservative estimates of clinical OAR objectives were computed using AD structures with spatial expansion buffers to account for potential delineation uncertainties. OARs with estimated dose metrics below clinical tolerances were deemed low priority and excluded from MD and/or manual review. Final plans were then optimized using high-priority MD OARs and low-priority AD OARs and compared with reference plans generated using all MD OARs. Multiple different spatial buffers were used to accommodate different potential delineation uncertainties. RESULTS: Sixty-seven out of 201 total OARs were identified as low-priority using the proposed methodology, which permitted a 33% reduction in structures requiring manual delineation/review. Plans optimized using low-priority AD OARs without review or modification met all planning objectives that were met when all MD OARs were used, indicating clinical equivalence. CONCLUSIONS: Prioritizing OARs using estimated dose distributions allowed a substantial reduction in required MD and review without affecting clinically relevant dosimetry.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Aliotta E, Nourzadeh H, Choi W, et al. An Automated Workflow to Improve Efficiency in Radiation Therapy Treatment Planning by Prioritizing Organs at Risk. Adv Radiat Oncol. 2020. PMID: 33305095. doi:10.1016/j.adro.2020.06.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。