乳腺癌放疗中左前降支 delineation 的安全边界
该研究纳入45例2015–2018年左侧乳腺癌辅助放疗患者,通过心脏门控CT评估左前降支(LAD)直径与运动,发现LAD运动在开口处最大,直径随距开口距离减小,建议以直径10 mm圆柱体作为LAD delineation安全边界,需独立验证。
要点
- LAD运动在开口处最大,远离开口后总体恒定。
- LAD直径随距开口距离减小:开口4.9 mm、回旋支3.9 mm、第二对角支3.5 mm、第二对角支3.1 mm。
- 建议LAD delineation安全边界为直径10 mm圆柱体。
核心结论
- 建议使用直径10 mm的圆柱体作为LAD delineation的安全边界,需在独立乳腺癌放疗患者系列中验证。
研究设计与样本
- 研究纳入45例2015–2018年左侧乳腺癌辅助放疗患者,行心脏门控CT及平扫/增强计划CT评估LAD直径与运动。
主要发现
- LAD运动在开口处最大,远离开口后总体恒定。
- LAD直径随距开口距离减小:开口4.9 mm、回旋支3.9 mm、第二对角支3.5 mm、第二对角支3.1 mm。
关键数值与推荐
- 建议LAD delineation安全边界为直径10 mm圆柱体。
临床怎么用
- 乳腺癌放疗计划设计时,可参考直径10 mm圆柱体作为LAD delineation安全边界以减少运动所致偏差。
局限性
- 研究结果需在独立乳腺癌放疗患者系列中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Cardiac toxicity after breast cancer (BC) radiation therapy is partly due to the large radiation doses to coronary arteries. The left anterior descending artery (LAD) is particularly exposed. A first step in achieving robust dose constraints to the LAD during treatment planning is homogeneous delineation based on guidelines. LAD delineation can be problematic due to heart movements. The aim of the study was to establish a safety margin for delineation of the LAD in patients with BC. METHODS AND MATERIALS: We studied 45 patients with left-sided BC who had an indication for adjuvant radiation therapy between 2015 and 2018. They all underwent cardiac-gated computed tomography scan, as well as planning computed tomography scans with or without contrast agents, to assess LAD diameter and movements. Cardiac-gated computed tomography scan was performed during monitoring of the cardiac cycle. Acquisition was launched immediately after contrast injection (arterial sequence), with deep-inspiration breath hold and use of a beta-receptor blocking agent. By manually reviewing each scan, the LAD positions and diameter were defined at 20 different phases of the cardiac cycle at 5 different sites: ostium (OS), circumflex bifurcation (bfc), first diagonal bfc, second diagonal (D2) bfc, and apex (right coronary anastomosis). RESULTS: Movement of the LAD is maximal at the ostium and then constant overall even when far from its origin. The diameter decreases with the distance from ostium: 4.9 mm (OS), 3.9 mm (circumflex), 3.5 mm (D2), and 3.1 mm (D2). CONCLUSIONS: We suggest using a safety delineation margin consisting of a cylinder with a diameter of 10 mm surrounding the LAD. These findings must be validated in independent series of patients treated for BC.
引用
- Nicolas E, Khalifa N, Laporte C, et al. Safety Margins for the Delineation of the Left Anterior Descending Artery in Patients Treated for Breast Cancer. Int J Radiat Oncol Biol Phys. 2020. PMID: 32861818. doi:10.1016/j.ijrobp.2020.08.051
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。