文献速递胸部肿瘤放疗放疗物理与技术

小鼠心脏亚体积照射显示心脏基底部区域放射敏感性

Cardiac sub-volume targeting demonstrates regional radiosensitivity in the mouse heart.
PubMed 文献 · Radiother Oncol · 2020-07-12

该研究使用小动物影像引导放疗平台对C57BL/6小鼠心脏基底部、中部或心尖部单次照射16 Gy,随访50周。结果显示所有照射小鼠出现左心室舒张期壁厚度增加约0.2 mm,基底部照射组变化最显著且持续,功能下降最明显(p<0.01)。功能变化与平均心脏剂量和V5不相关(R2<0.1),提示全心脏剂量学参数不能预测亚体积照射的生理改变。

要点

  • 小鼠心脏基底部单次16 Gy照射导致最显著且持续的结构与功能损伤。
  • 全心脏剂量学参数(平均心脏剂量、V5)不能预测亚体积照射的生理变化。
  • 临床观察提示心脏基底部为关键放射敏感区域,本研究反向验证了该现象。

核心结论

  • 小鼠心脏亚体积照射首次证实心脏基底部是放射敏感区域,可导致最显著的结构和功能损伤。

研究设计与样本

  • 使用小动物影像引导放疗平台对C57BL/6小鼠心脏基底部、中部或心尖部单次照射16 Gy,于基线及治疗后每10周至50周行锥形束CT和超声心动图检查。

主要发现

  • 所有照射小鼠在治疗后10周出现左心室舒张期壁厚度增加约0.2 mm,基底部照射组变化最显著且持续。
  • 基底部照射组功能下降最显著,与对照组相比差异有统计学意义(p<0.01)。
  • 功能变化与平均心脏剂量和V5不相关(R2<0.1)。

临床怎么用

  • 放疗计划评估心脏剂量时,除全心脏剂量学参数外,应关注心脏基底部的受照剂量。

局限性

  • 研究为小鼠模型,结果向临床转化需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Radiation-induced cardiac toxicity (RICT) remains one of the most critical dose limiting constraints in radiotherapy. Recent studies have shown higher doses to the base of the heart are associated with worse overall survival in lung cancer patients receiving radiotherapy. This work aimed to investigate the impact of sub-volume heart irradiation in a mouse model using small animal image-guided radiotherapy. MATERIALS AND METHODS: C57BL/6 mice were irradiated with a single fraction of 16 Gy to the base, middle or apex of the heart using a small animal radiotherapy research platform. Cone beam CT and echocardiography were performed at baseline and at 10 week intervals until 50 weeks post-treatment. Structural and functional parameters were correlated with mean heart dose (MHD) and volume of heart receiving 5 Gy (V5). RESULTS: All irradiated mice showed a time dependent increase in left ventricle wall thickness in diastole of ~0.2 mm detected at 10 weeks post-treatment, with the most significant and persistent changes occurring in the heart base-irradiated animals. Similarly, statistically different functional effects (p < 0.01) were observed in base-irradiated animals which showed the most significant decreases compared to controls. The observed functional changes did not correlate with MHD and V5 (R2 < 0.1), indicating that whole heart dosimetry parameters do not predict physiological changes resulting from cardiac sub-volume irradiation. CONCLUSIONS: This is the first report demonstrating the structural and functional consequences of sub-volume targeting in the mouse heart and reverse translates clinical observations indicating the heart base as a critical radiosensitive region.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Ghita M, Gill EK, Walls GM, et al. Cardiac sub-volume targeting demonstrates regional radiosensitivity in the mouse heart. Radiother Oncol. 2020. PMID: 32663535. doi:10.1016/j.radonc.2020.07.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。