文献速递头颈部肿瘤放疗放疗物理与技术

深度学习与基于图谱模型在头颈部CT咀嚼肌快速自动分割中的比较

Deep learning vs. atlas-based models for fast auto-segmentation of the masticatory muscles on head and neck CT images.
PubMed 文献 · Radiat Oncol · 2020-07-20

本研究在56例头颈部CT图像上比较深度学习自动分割(DLAS)与商业图谱自动分割(ABAS)对咀嚼肌的勾画效果。DLAS在所有咀嚼肌上的分割精度均优于ABAS(p<0.05),且基于DLAS的轮廓剂量终点与手动分割更接近;两种方法在多数剂量指标上差异无统计学意义。

要点

  • DLAS对咀嚼肌的分割精度优于ABAS,平均DSC范围0.83–0.89 vs 0.79–0.85。
  • DLAS轮廓的剂量终点与手动分割更匹配,但多数ΔD指标无统计学差异。
  • 颞肌和翼内肌的观察者间变异性最高,两种算法在颞肌上得分最高。

核心结论

  • DLAS对头颈部放疗咀嚼肌的自动分割精度优于ABAS,剂量终点与手动分割无定性差异。

研究设计与样本

  • 在56例头颈部CT图像上手动分割配对咬肌、颞肌、翼内肌和翼外肌,随机分为训练集27例和验证集29例,比较DLAS与ABAS两种自动分割方法。

主要发现

  • DLAS在所有咀嚼肌分割上均优于ABAS(p<0.05)。
  • DLAS对咬肌、颞肌、翼内肌、翼外肌的平均DSC范围为0.83±0.03至0.89±0.02,ABAS为0.79±0.05至0.85±0.04。
  • DLAS在召回率、HD、HD95、MSD上也有改善。
  • 观察者间变异显示颞肌和翼内肌的DSC和MSD变异性最高,两种算法在颞肌上得分最高。
  • 除少数例外,DLAS和ABAS对所有结构的平均ΔD98%、ΔD95%、ΔD50%、ΔD2%均低于10%,无统计学差异(P>0.05)。

临床怎么用

  • DLAS可用于头颈部放疗中咀嚼肌的快速自动分割,精度优于ABAS,有助于剂量跟踪和减少放射性张口困难。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Impaired function of masticatory muscles will lead to trismus. Routine delineation of these muscles during planning may improve dose tracking and facilitate dose reduction resulting in decreased radiation-related trismus. This study aimed to compare a deep learning model with a commercial atlas-based model for fast auto-segmentation of the masticatory muscles on head and neck computed tomography (CT) images. MATERIAL AND METHODS: Paired masseter (M), temporalis (T), medial and lateral pterygoid (MP, LP) muscles were manually segmented on 56 CT images. CT images were randomly divided into training (n = 27) and validation (n = 29) cohorts. Two methods were used for automatic delineation of masticatory muscles (MMs): Deep learning auto-segmentation (DLAS) and atlas-based auto-segmentation (ABAS). The automatic algorithms were evaluated using Dice similarity coefficient (DSC), recall, precision, Hausdorff distance (HD), HD95, and mean surface distance (MSD). A consolidated score was calculated by normalizing the metrics against interobserver variability and averaging over all patients. Differences in dose (∆Dose) to MMs for DLAS and ABAS segmentations were assessed. A paired t-test was used to compare the geometric and dosimetric difference between DLAS and ABAS methods. RESULTS: DLAS outperformed ABAS in delineating all MMs (p < 0.05). The DLAS mean DSC for M, T, MP, and LP ranged from 0.83 ± 0.03 to 0.89 ± 0.02, the ABAS mean DSC ranged from 0.79 ± 0.05 to 0.85 ± 0.04. The mean value for recall, HD, HD95, MSD also improved with DLAS for auto-segmentation. Interobserver variation revealed the highest variability in DSC and MSD for both T and MP, and the highest scores were achieved for T by both automatic algorithms. With few exceptions, the mean ∆D98%, ∆D95%, ∆D50%, and ∆D2% for all structures were below 10% for DLAS and ABAS and had no detectable statistical difference (P > 0.05). DLAS based contours had dose endpoints more closely matched with that of the manually segmented when compared with ABAS. CONCLUSIONS: DLAS auto-segmentation of masticatory muscles for the head and neck radiotherapy had improved segmentation accuracy compared with ABAS with no qualitative difference in dosimetric endpoints compared to manually segmented contours.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Chen W, Li Y, Dyer BA, et al. Deep learning vs. atlas-based models for fast auto-segmentation of the masticatory muscles on head and neck CT images. Radiat Oncol. 2020. PMID: 32690103. doi:10.1186/s13014-020-01617-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。