前列腺癌外照射放疗的自适应策略:利用鲁棒优化管理几何不确定性
结果显示鲁棒计划在最差场景下仍能实现CTV最佳覆盖,且直肠和膀胱剂量显著降低,对膀胱和直肠充盈变化不敏感。
要点
- 离线自适应策略基于前5次kV-CBCT构建患者特异性内靶区。
- 鲁棒计划较标准计划显著改善CTV覆盖(D99 P=.008,D98 P=.02)。
- 鲁棒计划显著降低直肠和膀胱剂量,且对充盈变化不敏感。
核心结论
- 前列腺癌放疗中该离线自适应策略可行且安全,较标准PTV计划靶区覆盖更好、危及器官保护更优。
研究设计与样本
- 第一步基于前5次分次kV-CBCT数据确定患者特异性内靶区,用ANACONDA形变配准算法将CTV从参考计划CT传播至CBCT并由放疗医师审核。
- 第二步用基于最差场景优化的min-max鲁棒算法重新计划,并在残余CBCT上计算剂量分布,与原始标准计划比较。
主要发现
- 鲁棒计划在最差场景下仍实现CTV最佳覆盖,且直肠和膀胱剂量显著更低。
- 鲁棒计划CTV覆盖的D99(P=.008)和D98(P=.02)均显著优于标准计划。
- 直肠平均剂量和D2降低(P<.05),膀胱平均剂量和D2降低(P<.009),均具统计学意义。
- 鲁棒计划对膀胱和直肠充盈变化的敏感性较低。
关键数值与推荐
- CTV覆盖以D99(P=.008)和D98(P=.02)评估,鲁棒计划显著优于标准计划。
- 直肠平均剂量和D2降低(P<.05),膀胱平均剂量和D2降低(P<.009)。
临床怎么用
- 可利用前5次分次kV-CBCT构建患者特异性内靶区并据此鲁棒再计划,以改善靶区覆盖并降低直肠膀胱剂量。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We aim to develop and validate a new adaptive method for prostate cancer radiation therapy (RT), using an offline strategy to improve treatment personalization by modeling the internal target volume on individual basis and account for the residual set-up uncertainties by robust optimization. METHODS AND MATERIALS: Twenty patients with intermediate-high prostate cancer treated with radical radiation therapy were enrolled. The first step of the offline adaptive RT strategy is the identification of a patient-specific internal target volume based on the kV cone beam computed tomography (kV-CBCT) data sets acquired during the first 5 fractions. The deformable image registration algorithm ANACONDA was used to propagate the clinical target volumes (CTVs) from the reference-planning computed tomography to the CBCTs; these contours were assessed by a radiation oncologist. In the second step, the internal target volume was used to replan the treatment using a min-max robust algorithm based on the worst scenario optimization. The CTV coverage and organs-at-risk sparing achieved with the robust plan (RP) were analyzed and compared with the original standard plan, calculating the dose distributions on the residual CBCTs. RESULTS: The RP was shown to achieve optimal coverage of the CTV even in the worst scenario, with significantly lower doses to the rectum and bladder. CTV coverage of the RP was statistically better than the standard plan in terms of D99 (P = .008) and D98 (P = .02). Statistically significant mean dose reduction and D2 reduction were noted for the rectum (P < .05) and bladder (P < .009). Moreover, the RP appeared to be less sensitive to bladder and rectal filling. CONCLUSIONS: This adaptive strategy in prostate cancer radiation therapy is feasible and safe; it may be used to adapt the treatment with better target coverage and organs-at-risk sparing than standard planning target volume-based planning.
引用
- Ferrara E, Beldì D, Yin J, et al. Adaptive Strategy for External Beam Radiation Therapy in Prostate Cancer: Management of the Geometrical Uncertainties With Robust Optimization. Pract Radiat Oncol. 2020. PMID: 32464369. doi:10.1016/j.prro.2020.05.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。