文献速递头颈部肿瘤放疗放疗物理与技术

头颈癌IMRT中肿瘤空间邻近危及器官的精确毒性相关性

Precision toxicity correlates of tumor spatial proximity to organs at risk in cancer patients receiving intensity-modulated radiotherapy.
PubMed 文献 · Radiother Oncol · 2020-05-16

该研究基于200例头颈癌患者队列,利用肿瘤位置、体积及与危及器官的邻近度计算患者相似性,预测新患者接受IMRT后的放射性吞咽困难(RAD)。患者聚类与RAD显著相关(p < .0001),加入聚类标签后预测准确率从AUC 0.79提升至0.84。结果表明治疗前空间信息可稳健识别RAD高危患者群。

要点

  • 基于肿瘤空间邻近度的患者聚类与RAD显著相关(p < .0001)。
  • 基线特征AUC为0.79,加入聚类标签后提升至0.84。
  • 治疗前空间信息可稳健识别RAD高危患者群。

核心结论

  • 治疗前空间信息可稳健识别放射性吞咽困难高危患者群,基于相似性预测的器官平均剂量可作为器官风险的有效预测因子。

研究设计与样本

  • 基于200例接受根治性IMRT的头颈癌患者队列,从治疗前增强CT提取解剖特征,采用拓扑相似性度量计算患者相似性并预测正常组织平均剂量,经特征选择与聚类后使用逻辑回归交叉验证评估毒性风险。

主要发现

  • 200例患者中34例记录有放射性吞咽困难(RAD)。
  • 患者聚类与RAD显著相关(p < .0001)。
  • 使用预先建立的基线特征,受试者工作特征曲线下面积(AUC)为0.79,加入聚类标签后准确率提升至0.84。

临床怎么用

  • 可利用治疗前肿瘤空间位置、体积及与危及器官邻近度进行患者聚类,辅助识别RAD高危患者并改进毒性风险预测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Using a 200 Head and Neck cancer (HNC) patient cohort, we employ patient similarity based on tumor location, volume, and proximity to organs at risk to predict radiation-associated dysphagia (RAD) in a new patient receiving intensity modulated radiation therapy (IMRT). MATERIAL AND METHODS: All patients were treated using curative-intent IMRT. Anatomical features were extracted from contrast-enhanced tomography scans acquired pre-treatment. Patient similarity was computed using a topological similarity measure, which allowed for the prediction of normal tissues' mean doses. We performed feature selection and clustering, and used the resulting groups of patients to forecast RAD. We used Logistic Regression (LG) cross-validation to assess the potential toxicity risk of these groupings. RESULTS: Out of 200 patients, 34 patients were recorded as having RAD. Patient clusters were significantly correlated with RAD (p < .0001). The area under the receiver-operator curve (AUC) using pre-established, baseline features gave a predictive accuracy of 0.79, while the addition of our cluster labels improved accuracy to 0.84. CONCLUSION: Our results show that spatial information available pre-treatment can be used to robustly identify groups of RAD high-risk patients. We identify feature sets that considerably improve toxicity risk prediction beyond what is possible using baseline features. Our results also suggest that similarity-based predicted mean doses to organs can be used as valid predictors of risk to organs.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Wentzel A, Hanula P, van Dijk LV, et al. Precision toxicity correlates of tumor spatial proximity to organs at risk in cancer patients receiving intensity-modulated radiotherapy. Radiother Oncol. 2020. PMID: 32422303. doi:10.1016/j.radonc.2020.05.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。