指南与共识乳腺癌放疗

新辅助部分乳腺照射试验中MRI乳腺原发肿瘤勾画共识

Consensus on Contouring Primary Breast Tumors on MRI in the Setting of Neoadjuvant Partial Breast Irradiation in Trials.
指南 / 共识 · Pract Radiat Oncol · 2020-04-18

国际专家组通过三次会议制定并评估了MRI上乳腺原发肿瘤勾画共识,10例早期乳腺癌(cT1N0)勾画显示GTV的CI为0.28–0.77,CTV的CI为0.77–0.94,共识推荐在增强MRI注射对比剂后1–2分钟勾画所有可见肿瘤并包含瘤内标记。

要点

  • 共识推荐在增强MRI注射对比剂后1–2分钟勾画所有可见肿瘤。
  • 若肿瘤内放置标记物,勾画时应将其包含在内。
  • GTV均匀外扩20 mm生成CTV,需排除皮肤和胸壁。

核心结论

  • 试验中MRI乳腺原发肿瘤勾画已达成专家共识,在GTV均匀外扩20 mm条件下CTV的观察者间变异较低。

研究设计与样本

  • 国际乳腺放射肿瘤专家与乳腺放射科医生通过三次会议制定并评估勾画指南。
  • 第二次会议6名放射肿瘤医生按草案勾画10例早期乳腺癌(cT1N0)的GTV。
  • 第三次会议5名放射肿瘤医生使用共识指南重新勾画6例。

主要发现

  • 两次勾画合并后,平均GTV范围为0.19–2.44 cm³。
  • GTV的CI范围为0.28–0.77,CTV的CI范围为0.77–0.94。
  • GTV勾画变异最大见于肿瘤毛刺延伸、肿瘤附近有血管或瘤内有标记物、或腺体乳腺组织强化增加的情况。

关键数值与推荐

  • 共识推荐在增强MRI注射对比剂后1–2分钟勾画所有可见肿瘤。
  • 若肿瘤内插入标记物,勾画时应包含该标记物。
  • GTV均匀外扩20 mm生成CTV,排除皮肤和胸壁。

临床怎么用

  • 在试验背景下,可按共识在增强MRI注射对比剂后1–2分钟勾画所有可见肿瘤并包含瘤内标记物。
  • CTV可由GTV均匀外扩20 mm生成,但需排除皮肤和胸壁。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Our purpose was to present and evaluate expert consensus on contouring primary breast tumors on magnetic resonance imaging (MRI) in the setting of neoadjuvant partial breast irradiation in trials. METHODS AND MATERIALS: Expert consensus on contouring guidelines for target definition of primary breast tumors on contrast-enhanced MRI in trials was developed by an international team of experienced breast radiation oncologists and a dedicated breast radiologist during 3 meetings. At the first meeting, draft guidelines were developed through discussing and contouring 2 cases. At the second meeting 6 breast radiation oncologists delineated gross tumor volume (GTV) in 10 patients with early-stage breast cancer (cT1N0) according to draft guidelines. GTV was expanded isotropically (20 mm) to generate clinical target volume (CTV), excluding skin and chest wall. Delineations were reviewed for disagreement and guidelines were clarified accordingly. At the third meeting 5 radiation oncologists redelineated 6 cases using consensus-based guidelines. Interobserver variation of GTV and CTV was assessed using generalized conformity index (CI). CI was calculated as the sum of volumes each pair of observers agreed upon, divided by the sum of encompassing volumes for each pair of observers. RESULTS: For the 2 delineation sessions combined, mean GTV ranged between 0.19 and 2.44 cm3, CI for GTV ranged between 0.28 and 0.77, and CI for CTV between 0.77 and 0.94. The largest interobserver variation in GTV delineations was observed in cases with extended tumor spiculae, blood vessels near or markers within the tumor, or with increased enhancement of glandular breast tissue. Consensus-based guidelines stated to delineate all visible tumors on contrast enhanced-MRI scan 1 to 2 minutes after contrast injection and if a marker was inserted in the tumor to include this. CONCLUSIONS: Expert-based consensus on contouring primary breast tumors on MRI in trials has been reached. This resulted in low interobserver variation for CTV in the context of a uniform 20 mm GTV to CTV expansion margin.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Vasmel JE, Groot Koerkamp ML, Kirby AM, et al. Consensus on Contouring Primary Breast Tumors on MRI in the Setting of Neoadjuvant Partial Breast Irradiation in Trials. Pract Radiat Oncol. 2020. PMID: 32315784. doi:10.1016/j.prro.2020.03.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。