MRI引导食管癌放疗的三维靶区覆盖评估
结果显示10mm边距下骨配准覆盖118/132分次(89%),软组织配准覆盖123/132分次(93%),覆盖不足主要见于近贲门及交界处远端肿瘤。
要点
- 10mm边距下骨配准覆盖89%分次,软组织配准覆盖93%分次。
- 靶区覆盖不足主要发生于近贲门及交界处的远端肿瘤。
- 在线MR引导仅适度改善覆盖,高适形照射需每日自适应计划。
核心结论
- 在线MR引导软组织配准相比CBCT骨配准仅适度改善几何靶区覆盖概率。
- 实现高适形靶区照射需实施每日基于当日解剖生成新计划的在线自适应流程。
研究设计与样本
- 每次扫描勾画GTV和CTV,随访扫描分别刚性配准至骨性解剖和CTV本身以模拟两种在线摆位策略。
- 以0至15mm、步长1mm的各向同性外扩评估传播CTV的几何覆盖概率。
主要发现
- 10mm边距下骨配准可解决118/132分次(89%)的分次间变化。
- 10mm边距下CTV直接配准(软组织配准)时123/132分次(93%)获得充分覆盖。
- 靶区覆盖不足主要见于近交界处及进入贲门的远端肿瘤。
关键数值与推荐
- 各向同性外扩边距范围0mm至15mm,增量1mm。
- 骨配准10mm边距覆盖118/132分次(89%)。
- 软组织配准10mm边距覆盖123/132分次(93%)。
临床怎么用
- 在线MR引导软组织配准较CBCT骨配准仅适度提升食管癌靶区几何覆盖。
- 高适形靶区照射需配合在线自适应工作流,每日按当日解剖重新生成计划。
- 近贲门及交界处远端肿瘤应特别关注靶区覆盖不足风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: This study aimed to quantify the coverage probability for esophageal cancer radiotherapy as a function of a preset margin for online MR-guided and (CB)CT-guided radiotherapy. METHODS: Thirty esophageal cancer patients underwent six T2-weighted MRI scans, 1 prior to treatment and 5 during neoadjuvant chemoradiotherapy at weekly intervals. Gross tumor volume (GTV) and clinical target volume (CTV) were delineated on each individual scan. Follow-up scans were rigidly aligned to the bony anatomy and to the clinical target volume itself, mimicking two online set-up correction strategies: a conventional CBCT-guided set-up and a MR-guided set-up, respectively. Geometric coverage probability of the propagated CTVs was assessed for both set-up strategies by expanding the reference CTV with an isotropic margin varying from 0 mm to 15 mm with an increment of 1 mm. RESULTS: A margin of 10 mm could resolve the interfractional changes for 118 out of the 132 (89%) analyzed fractions when applying a bone-match registration, whereas the CTV was adequately covered in 123 (93%) fractions when the registration was directly performed at the CTV itself (soft-tissue registration). Closer analyses revealed that target coverage violation predominantly occurred for distal tumors near the junction and into the cardia. CONCLUSION: Online MR-guided soft-tissue registration protocols exhibited modest improvements of the geometric target coverage probability as compared to online CBCT-guided bone match protocols. Therefore, highly conformal target irradiation using online MR-guidance can only be achieved by implementing on-table adaptive workflows where new treatment plans are daily generated based on the anatomy of the day.
引用
- Boekhoff MR, Defize IL, Borggreve AS, et al. 3-Dimensional target coverage assessment for MRI guided esophageal cancer radiotherapy. Radiother Oncol. 2020. PMID: 32234611. doi:10.1016/j.radonc.2020.03.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。