文献速递头颈部肿瘤放疗放疗物理与技术

320 MHz扫描声学显微镜对头颈癌放疗后人类牙齿弹性特性的声学诊断

Acoustic diagnosis of elastic properties of human tooth by 320 MHz scanning acoustic microscopy after radiotherapy treatment for head and neck cancer.
PubMed 文献 · Radiat Oncol · 2020-02-17

本研究采用320 MHz扫描声学显微镜(SAM)评估头颈癌放疗后牙齿的弹性特性变化。研究纳入45颗健康人类第三磨牙,在照射前后测量声阻抗。结果显示,釉质在30 Gy和60 Gy组声阻抗显著降低,牙本质在20、30和60 Gy组显著降低。结论提示SAM可作为可视化并追踪安全剂量限值的工具。

要点

  • 320 MHz SAM可在微米级评估放疗后牙齿釉质和牙本质的声阻抗变化。
  • 釉质声阻抗在30 Gy和60 Gy照射后显著降低(p < 0.05)。
  • 牙本质声阻抗在20、30和60 Gy照射后显著降低(p < 0.05)。

核心结论

  • 320 MHz扫描声学显微镜是一种安全的声学检查设备,可能有助于可视化并追踪头颈癌放疗中防止严重牙齿损伤的安全剂量限值。

研究设计与样本

  • 前瞻性研究,采用320 MHz扫描声学显微镜(方位分辨率4.7 μm)评估45颗健康人类第三磨牙照射前后的声阻抗。
  • 每组建9个样本(对照组、2 Gy、8 Gy、20 Gy、30 Gy和60 Gy组),获取声学图像进行定性分析。
  • 使用扫描电子显微镜(SEM)图像建立牙齿微力学与形态学特征之间的关系。
  • 统计分析采用Student t检验和Mann-Whitney U检验(p < .05),SEM图像进行定性评估。

主要发现

  • 牙本质在20、30和60 Gy组声阻抗值较未照射组显著降低(6.52 ± 0.43 MRayl、5.71 ± 0.66 MRayl和4.82 ± 0.53 MRayl;p < 0.05)。

关键数值与推荐

  • 牙本质声阻抗在20 Gy组为6.52 ± 0.43 MRayl,30 Gy组为5.71 ± 0.66 MRayl,60 Gy组为4.82 ± 0.53 MRayl,均显著低于未照射组(p < 0.05)。

临床怎么用

  • 320 MHz SAM可作为声学检查工具,用于头颈癌放疗后牙齿微力学变化的可视化评估。
  • 该技术可能有助于追踪防止严重牙齿损伤的安全剂量限值。

局限性

  • 原文未报告

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: On the elastic profiles of human teeth after radiotherapy for head and neck cancers, generation of dental complications, which may bring several side effects preventing the quality of life, has not well clarified. Thus, we aimed to show the applicability of using 320 MHz Scanning Acoustic Microscopy (SAM) in the evaluation of the tooth damage acoustically at the micrometer level following radiation therapy, and also in the determination of the safe dose limits to impede severe dental damage. METHODS: This prospective study was performed by SAM employed at 320 MHz by an azimuthal resolution of 4.7 μm resolving enamel and dentin. A total of 45 sound human third molar teeth collected between September 2018 and May 2019 were used for the acoustic impedance measurements pre- and post irradiation. Nine samples for each group (control, 2 Gy, 8 Gy, 20 Gy, 30 Gy and 60 Gy) were evaluated to acquire the acoustic images and perform a qualitative analysis. Scanning Electron Microscopy (SEM) images were obtained to establish a relationship between micromechanical and morphological characteristics of the teeth. Statistical analysis was conducted using the Student t-test succeded by Mann-Whitney U investigation (p < .05), while SEM images were assessed qualitatively. RESULTS: The analysis included 45 sound teeth collected from men and women 18 to 50 years old. Post irradiation micromechanical variations of human teeth were significant only in the radiation groups of 30 Gy and 60 Gy compared to pre-irradiation group for enamel (7.24 ± 0.18 MRayl and 6.49 ± 028 MRayl; p < 0.05, respectively). Besides, the teeth subjected to radiation doses of 20, 30 and 60 Gy represented significantly lower acoustic impedance values relative to non-irradiated group for dentin (6.52 ± 0.43 MRayl, 5.71 ± 0.66 MRayl and 4.82 ± 0.53 MRayl p < 0.05), respectively. CONCLUSIONS: These results are evidence for a safe acoustic examination device which may be a useful tool to visualize and follow the safe dose limits to impede severe dental damage through the radiation therapy treatment for head and neck cancers.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Demirkan I, Yaprak G, Ceylan C, et al. Acoustic diagnosis of elastic properties of human tooth by 320 MHz scanning acoustic microscopy after radiotherapy treatment for head and neck cancer. Radiat Oncol. 2020. PMID: 32066465. doi:10.1186/s13014-020-01486-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。