分弧部分野VMAT用于海马保护性全脑放疗的剂量学比较
本研究为回顾性计划研究,纳入20例脑转移患者的CT与MRI图像,比较双弧常规VMAT(dac-VMAT)与分弧部分野VMAT(sapf-VMAT)在海马保护性全脑放疗中的剂量学差异。处方为30 Gy/10次,结果显示sapf-VMAT较dac-VMAT显著降低海马及双眼剂量,且全脑PTV覆盖未受影响。
要点
- sapf-VMAT较dac-VMAT显著降低海马平均剂量(9.16 Gy vs 10.85 Gy,p<0.05)。
- sapf-VMAT较dac-VMAT显著降低海马D100%与Dmax,双眼Dmean亦显著降低。
- 两种技术全脑PTV覆盖均未受损。
核心结论
- sapf-VMAT较dac-VMAT显著降低海马及双眼剂量,同时保持全脑PTV覆盖。
研究设计与样本
- 回顾性计划研究,纳入20例脑转移患者的CT与MRI图像,海马由单一放疗医师按RTOG 0933图谱手动勾画。
- 每例患者分别生成dac-VMAT与sapf-VMAT计划,处方剂量30 Gy/10次,剂量学参数采用配对t检验比较。
主要发现
- sapf-VMAT海马平均D100%为7.86 Gy,显著低于dac-VMAT的9.23 Gy(p=0.001)。
- sapf-VMAT海马Dmax为13.23 Gy,显著低于dac-VMAT的16.33 Gy(p=0.001)。
- sapf-VMAT海马平均剂量为9.16 Gy,显著低于dac-VMAT的10.85 Gy(p<0.05)。
- 双眼Dmean在sapf-VMAT中均显著低于dac-VMAT(p<0.05)。
- 两种技术全脑PTV覆盖均未受损害。
临床怎么用
- 在需行海马保护性全脑放疗的脑转移患者中,可优先考虑sapf-VMAT以降低海马和双眼剂量。
局限性
- 本研究为回顾性计划研究,样本量为20例,海马由单一放疗医师勾画。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although whole brain radiation therapy (WBRT) provides palliation and prophylaxis, reduces local recurrence probability and improves overall survival, it is evident that WBRT is associated with neurocognitive deficits due to radiation induced damage of the hippocampus. Therefore, minimizing hippocampal dose to the least possible level is of high clinical relevance. In dual-arc conventional volumetric modulated arc therapy (dac-VMAT), the large irradiation field for whole brain planned target volume (PTV) requires a wide jaw opening in which substantial low dose volume to the hippocampus may be produced due to suboptimal multi-leaf collimator (MLC) movements. The present study investigates the potential of a radiation therapy technique with split-arc and reduced field size, namely split-arc partial-field volumetric modulated arc therapy (sapf-VMAT) to spare the hippocampus during WBRT. METHODS: Computed tomography and magnetic resonance images of 20 patients with brain metastases were retrieved in this retrospective planning study. The hippocampus was manually delineated by single radiation oncologist strictly following the RTOG 0933 atlas definition. Plans delivering 30 Gy in 10 fractions were generated for each patient using dac-VMAT and sapf-VMAT. Dosimetric parameters from both techniques were compared by paired t-test. RESULTS: The results demonstrated that radiation dose to the hippocampus was significantly reduced using sapf-VMAT relative to dac-VMAT plans. sapf-VMAT (7.86Gy, p = 0.001) had significantly lowered average D100% compared to dac-VMAT (9.23 Gy). Decrease in hippocampus Dmax using sapf-VMAT (13.23 Gy, p = 0.001) was statistically significant when compared to dac-VMAT (16.33 Gy). The resulting mean dose to the hippocampus was 9.16 Gy for the for sapf-VMAT. Mean dose of sapf-VMAT was significantly lower than dac-VMAT (10.85 Gy, p < 0.05). In both eyes, sapf-VMAT demonstrated significantly lower Dmean compared to dac-VMAT (p < 0.05). Whole brain PTV coverage was not compromised in both techniques. CONCLUSION: sapf-VMAT has demonstrated significant dose reduction to the hippocampus and both eyes compared to dac-VMAT.
引用
- Yuen AHL, Wu PM, Li AKL, et al. Volumetric modulated arc therapy (VMAT) for hippocampal-avoidance whole brain radiation therapy: planning comparison with Dual-arc and Split-arc partial-field techniques. Radiat Oncol. 2020. PMID: 32070385. doi:10.1186/s13014-020-01488-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。