文献速递胸部肿瘤放疗放疗物理与技术

高功能通气区剂量提升质子与光子肺癌放疗放射性肺炎预测

Dose to Highly Functional Ventilation Zones Improves Prediction of Radiation Pneumonitis for Proton and Photon Lung Cancer Radiation Therapy.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2020-01-25

基于吸气与呼气CT形变生成三维肺通气图并划分高、低通气区进行剂量分析,发现高通气区接受≥20 Gy体积(vV20Gy_high)对放射性肺炎的预测优于传统V20Gy。

要点

  • 高通气区定义为通气值较高的45%至60%区域。
  • vV20Gy_high可显著预测放射性肺炎,优于传统V20Gy。
  • 低通气区剂量与放射性肺炎关系不显著。

核心结论

  • 肺高通气区域剂量可改善光子和质子放疗的放射性肺炎预测。

研究设计与样本

  • 利用Advanced Normalization Tools形变吸气与呼气模拟CT,生成三维肺通气图并划分高、低通气区进行剂量分析。
  • 采用受试者工作特征曲线分析确定最佳通气截断值,单因素逻辑回归关联分区剂量与放射性肺炎风险,非参数随机森林进行多变量重要性评估。

主要发现

  • 最佳高通气区定义为通气值较高的45%至60%区域。
  • 通气平均肺剂量和通气V5Gy呈现相似趋势。
  • 多变量重要性评估显示vV20Gy_high、vV5_high和平均肺剂量是质子队列最显著参数,联合曲线下面积为0.78。

关键数值与推荐

  • 高通气区截断值为通气值较高的45%至60%。
  • 质子队列联合vV20Gy_high、vV5_high和平均肺剂量的曲线下面积为0.78。

临床怎么用

  • 计划评估时可关注高通气区接受≥20 Gy的体积(vV20Gy_high),辅助预测放射性肺炎风险。
  • 低通气区剂量对放射性肺炎预测价值有限,优化时应优先考虑高通气区剂量约束。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We hypothesized that the radiation dose in high-ventilation portions of the lung better predicts radiation pneumonitis (RP) outcome for patients treated with proton radiation therapy (PR) and photon radiation therapy (PH). METHODS AND MATERIALS: Seventy-four patients (38 protons, 36 photons) with locally advanced non-small cell lung cancer treated with concurrent chemoradiation therapy were identified, of whom 24 exhibited RP (graded using Common Terminology Criteria for Adverse Events v4.0) after PR or PH, and 50 were negative controls. The inhale and exhale simulation computed tomography scans were deformed using Advanced Normalization Tools. The 3-dimensional lung ventilation maps were derived from the deformation matrix and partitioned into low- and high-ventilation zones for dosimetric analysis. Receiver operating curve analysis was used to study the power of relationship between RP and ventilation zones to determine an optimal ventilation cutoff. Univariate logistic regression was used to correlate dose in high- and low-ventilation zones with risk of RP. A nonparametric random forest process was used for multivariate importance assessment. RESULTS: The optimal high-ventilation zone definition was determined to be the higher 45% to 60% of the ventilation values. The parameter vV20Gy_high (high ventilation volume receiving ≥20 Gy) was found to be a significant indicator for RP (PH: P = .002, PR: P = .035) with improved areas under the curve compared with the traditional V20Gy for both photon and proton cohorts. The relationship of RP with dose to the low-ventilation zone of the lung was insignificant (PH: P = .123, PR: P = .661). Similar trends were observed for ventilation mean lung dose and ventilation V5Gy. Multivariate importance assessment determined that vV20Gy_high, vV5_high, and mean lung dose were the most significant parameters for the proton cohort with a combined area under the curve of 0.78. CONCLUSION: Dose to the high-ventilated regions of the lung can improve predictions of RP for both PH and PR.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. O'Reilly S, Jain V, Huang Q, et al. Dose to Highly Functional Ventilation Zones Improves Prediction of Radiation Pneumonitis for Proton and Photon Lung Cancer Radiation Therapy. Int J Radiat Oncol Biol Phys. 2020. PMID: 31987966. doi:10.1016/j.ijrobp.2020.01.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。