食管肿瘤运动量化及不同图像引导校正策略研究
结果显示肿瘤运动各向异性明显,基于CTV配准所需PTV外扩最小,头脚方向需大于常用值。
要点
- 食管肿瘤呼吸运动头脚方向平均峰峰值0.92 cm,明显大于左右0.20 cm和前后0.34 cm。
- 基于CTV配准所需PTV外扩最小:左右0.8 cm、头脚1.1 cm、前后0.7 cm。
- 头脚方向PTV外扩需大于常用值,建议采用非均匀外扩。
核心结论
- 食管肿瘤放疗期间存在显著且各向异性的位置变异,应考虑非均匀PTV外扩。
- 基于CTV的图像引导配准策略可缩小所需PTV外扩,优于骨配准和膈肌配准。
研究设计与样本
- 前瞻性队列研究(NCT02139488),纳入接受卡铂联合紫杉醇同步放化疗(41.4-50.4 Gy/23-28次)的食管癌患者。
- 诊断性超声内镜下向食管肿瘤植入金标,采集4D计划CT和每日4D CBCT。
- 将CBCT分别基于骨(3D)、隆突、膈肌、CTV和金标(4D)配准至计划CT,以金标位置为真实肿瘤位置,计算各配准策略所需PTV外扩。
主要发现
- 计划CT上平均呼吸肿瘤运动峰峰值:左右0.20 cm、头脚0.92 cm、前后0.34 cm。
- 含平均运动幅度的所需PTV外扩随图像引导校正策略不同:左右0.8-1.0 cm、头脚1.1-1.6 cm、前后0.7-0.9 cm。
- 基于CTV配准所需PTV外扩最小:左右0.8 cm、头脚1.1 cm、前后0.7 cm。
- 基于骨配准所需PTV外扩:左右1.0 cm、头脚1.3 cm、前后0.7 cm;基于膈肌配准增加PTV外扩。
关键数值与推荐
- 基于CTV配准的PTV外扩:左右0.8 cm、头脚1.1 cm、前后0.7 cm。
- 基于骨配准的PTV外扩:左右1.0 cm、头脚1.3 cm、前后0.7 cm。
- 各策略所需PTV外扩范围:左右0.8-1.0 cm、头脚1.1-1.6 cm、前后0.7-0.9 cm。
临床怎么用
- 食管癌图像引导放疗可优先考虑基于CTV的配准校正策略以缩小PTV外扩。
- 头脚方向PTV外扩应大于常用值,并采用非均匀外扩。
- 基于膈肌配准会增加所需PTV外扩,不宜作为优选校正策略。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To accurately quantify esophageal tumor position variability and to optimize image guided correction strategies. MATERIAL AND METHODS: Esophageal cancer patients receiving chemoradiotherapy (41.4-50.4 Gy in 23-28 fractions combined with carboplatin plus paclitaxel) were included in a prospective cohort study (NCT02139488). Gold fiducial markers were inserted into the esophageal tumors during diagnostic endoscopic ultrasound. Four-dimensional (4D) planning computed tomography (CT) and daily 4D cone beam (CB) CT scans were acquired. Each CBCT was registered to the planning CT using different regions of interest (bone; 3D), and carina, diaphragm, clinical target volume (CTV), and fiducial markers (4D) for alignment and using the fiducial markers as the true tumor position. Subsequently, a planning target volume (PTV) margin accounting for residual uncertainties, including the average respiratory motion, was calculated for each of these registrations. RESULTS: Fifty-six patients with tumors located in the proximal (n = 1), mid (n = 7), or distal esophagus (n = 25) or at the gastroesophageal junction (n = 23) were included. The average peak-to-peak respiratory tumor motion was 0.20, 0.92, and 0.34 cm on the planning CT in left-right (LR), cranial-caudal (CC), and anterior-posterior (AP) directions, respectively. The required PTV margin with average motion amplitude, depending on the correction strategy used for image guidance, ranged from 0.8 cm to 1.0 cm, 1.1 cm to 1.6 cm, and 0.7 cm to 0.9 cm in LR, CC, and AP direction, respectively. A registration based on the CTV resulted in the smallest PTV margins (0.8, 1.1, and 0.7 cm in LR, CC, and AP direction, respectively). For bone registration the calculated PTV margins were 1.0, 1.3, and 0.7 cm in LR, CC, and AP directions, respectively. The registration based on the diaphragm increased PTV margins. CONCLUSIONS: Substantial and anisotropic position variability of esophageal tumors was observed during radiation therapy, and nonuniform margins should be considered. Cranial-caudal PTV margins need to be larger than those commonly used. Target positioning during image-guided radiotherapy could be improved with a CTV registration-based correction strategy.
引用
- Voncken FEM, Nakhaee S, Stam B, et al. Quantification of Esophageal Tumor Motion and Investigation of Different Image-Guided Correction Strategies. Pract Radiat Oncol. 2019. PMID: 31786235. doi:10.1016/j.prro.2019.11.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。