文献速递中枢神经肿瘤放疗头颈部肿瘤放疗泌尿生殖与妇科肿瘤放疗

深度学习自动分割与专家观察者间变异性的比较

Comparing deep learning-based auto-segmentation of organs at risk and clinical target volumes to expert inter-observer variability in radiotherapy planning.
PubMed 文献 · Radiother Oncol · 2019-12-05

该研究在独立数据集上比较深度学习自动分割轮廓(DC)与多位放射肿瘤科医生(RO)专家轮廓(EC)在CNS、头颈和前列腺放疗OAR及CTV上的差异。DC由单一RO用公开数据训练。结果显示OAR的DSC和95%HD差异极小,CTV差异较明显;DC分割时间远短于EC。结论认为DC精度与专家观察者间变异性相当,有望改善放疗计划流程与资源利用。

要点

  • DC在OAR上DSC和95%HD与EC差异极小,CTV差异较明显。
  • DC分割时间0.4–0.6分钟,EC为7.7–26.6分钟。
  • 单RO训练的DC精度可与专家观察者间变异性相当。

核心结论

  • 在独立数据集上,单一RO训练的DC精度与放疗计划轮廓的专家观察者间变异性相当。

研究设计与样本

  • 研究比较CNS、头颈和前列腺放疗OAR及CTV的DC与多位RO创建的EC,DC由单一RO在公开数据上训练的深度学习软件生成。
  • 共纳入60份计划CT,含60套CNS、53套头颈和50套前列腺轮廓,每份有2–4个EC。
  • 轮廓比较采用Dice相似系数(DSC)和95%豪斯多夫距离(HD)。

主要发现

  • DC与EC平均轮廓时间:CNS 0.4 vs 7.7分钟,头颈0.6 vs 26.6分钟,前列腺0.4 vs 21.3分钟。
  • OAR比较中DC的DSC和95%HD差异极小,CTV比较差异更明显。

临床怎么用

  • 深度学习自动分割可减少OAR和CTV勾画时间,可能显著改善放疗计划工作流程与资源利用。
  • CTV自动分割与专家间差异较明显,临床使用时仍需重点审核。

局限性

  • DC由单一RO在公开数据上训练,验证数据集与训练数据集的关系未在摘要中说明。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Deep learning-based auto-segmented contours (DC) aim to alleviate labour intensive contouring of organs at risk (OAR) and clinical target volumes (CTV). Most previous DC validation studies have a limited number of expert observers for comparison and/or use a validation dataset related to the training dataset. We determine if DC models are comparable to Radiation Oncologist (RO) inter-observer variability on an independent dataset. METHODS: Expert contours (EC) were created by multiple ROs for central nervous system (CNS), head and neck (H&N), and prostate radiotherapy (RT) OARs and CTVs. DCs were generated using deep learning-based auto-segmentation software trained by a single RO on publicly available data. Contours were compared using Dice Similarity Coefficient (DSC) and 95% Hausdorff distance (HD). RESULTS: Sixty planning CT scans had 2-4 ECs, for a total of 60 CNS, 53 H&N, and 50 prostate RT contour sets. The mean DC and EC contouring times were 0.4 vs 7.7 min for CNS, 0.6 vs 26.6 min for H&N, and 0.4 vs 21.3 min for prostate RT contours. There were minimal differences in DSC and 95% HD involving DCs for OAR comparisons, but more noticeable differences for CTV comparisons. CONCLUSIONS: The accuracy of DCs trained by a single RO is comparable to expert inter-observer variability for the RT planning contours in this study. Use of deep learning-based auto-segmentation in clinical practice will likely lead to significant benefits to RT planning workflow and resources.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Wong J, Fong A, McVicar N, et al. Comparing deep learning-based auto-segmentation of organs at risk and clinical target volumes to expert inter-observer variability in radiotherapy planning. Radiother Oncol. 2019. PMID: 31812930. doi:10.1016/j.radonc.2019.10.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。