文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

笔束扫描与被动散射/均匀扫描质子治疗局限期前列腺癌的毒性比较:PCG 001-09分析

Proton beam therapy delivered using pencil beam scanning vs. passive scattering/uniform scanning for localized prostate cancer: Comparative toxicity analysis of PCG 001-09.
PubMed 文献 · Clin Transl Radiat Oncol · 2019-08-31

基于PCG 001-09前瞻性多中心注册研究,比较笔束扫描(PBS)与被动散射/均匀扫描(PS/US)质子治疗低中危前列腺癌的急性和晚期胃肠(GI)及泌尿生殖(GU)毒性。PBS组急性≥2级GU毒性显著高于PS/US组(21.9% vs 15.1%,P<0.01),多因素分析PBS与急性≥2级GU毒性增加显著相关(RR=1.57,P<0.001);急性≥2级GI毒性和晚期≥2级GI/GU毒性两组无显著差异。

要点

  • PBS组急性≥2级GU毒性显著高于PS/US组(21.9% vs 15.1%,P<0.01)。
  • 多因素分析PBS与急性≥2级GU毒性增加显著相关(RR=1.57,P<0.001)。
  • 两组晚期≥2级GI和GU毒性无显著差异。

核心结论

  • PBS质子治疗局限期前列腺癌的急性≥2级GU毒性显著高于PS/US,但晚期GI和GU毒性无显著差异。

研究设计与样本

  • 前瞻性多中心注册研究PCG 001-09,纳入低中危前列腺癌男性,PS/US组n=1105,PBS组n=238。

主要发现

  • PBS组急性≥2级GI毒性2.9%,PS/US组2.1%,差异无统计学意义(P=0.47)。
  • PBS组急性≥2级GU毒性21.9%,PS/US组15.1%,差异有统计学意义(P<0.01)。
  • 多因素分析显示PBS与急性≥2级GU毒性增加显著相关(RR=1.57,P<0.001)。
  • 两组晚期≥2级GI和GU毒性无显著差异。

临床怎么用

  • 采用PBS质子治疗前列腺癌时需关注急性GU毒性增加的风险,加强相应监测与管理。

局限性

  • PBS组样本量(n=238)明显小于PS/US组(n=1105)。
  • 急性GU毒性差异的机制有待进一步评估,需前瞻性数据验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Patient-level benefits of proton beam therapy (PBT) relative to photon therapy for prostate cancer (PC) continue to be the focus of debate. Although trials comparing the two modalities are underway, most are being conducted using "conventional" PBT (passive scattering/uniform scanning [PS/US]) rather than pencil beam scanning (PBS). The dosimetric benefits of PBS are well-known, but comparative data are limited. This analysis compares PBS toxicity rates with those of PS/US in a prospective multicenter registry. METHODS: We evaluated acute/late gastrointestinal (GI) and genitourinary (GU) toxicity rates for men with low-to-intermediate risk PC enrolled in PCG 001-09. Acute toxicities with the two techniques were compared using χ2 tests, and the cumulative incidence methods for late toxicity. Multivariable analyses (MVAs) for acute toxicity were performed using logistic regression, and cox proportional hazards models for late toxicity. RESULTS: Patients were treated using PS/US (n = 1105) or PBS (n = 238). Acute grade ≥2 GI toxicity in PBS did not significantly differ from that with PS/US (2.9% and 2.1%, respectively; P = 0.47). Acute grade ≥2 GU toxicity was significantly higher with PBS (21.9% and 15.1%; P < 0.01). In MVA, PBS was significantly associated with increased acute grade ≥2 GU toxicity (RR = 1.57, p < 0.001). Late grade ≥2 GI and GU toxicities did not differ significantly between groups. CONCLUSIONS: This is the first multi-institutional comparative effectiveness evaluation of PBT techniques in PC. Differences in acute GU toxicity warrant further evaluation, and highlight the urgent need for prospective data using PBT.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Mishra MV, Khairnar R, Bentzen SM, et al. Proton beam therapy delivered using pencil beam scanning vs. passive scattering/uniform scanning for localized prostate cancer: Comparative toxicity analysis of PCG 001-09. Clin Transl Radiat Oncol. 2019. PMID: 31650043. doi:10.1016/j.ctro.2019.08.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。