肺部立体定向体部放疗剂量梯度与PTV体积的多中心回顾分析
作者认为该关系可用于PTV<85 cm3计划的百分位GM评估与质控。
要点
- 周边型肺SBRT计划中仅142/317无RTOG 0915剂量学偏差。
- 梯度测量与PTV体积呈幂函数关系GM=0.564 V^0.215。
- PTV<85 cm3计划可参照既往计划给出百分位GM。
核心结论
- 临床可实现的剂量梯度依赖于PTV大小,并可用幂函数GM=0.564 V^0.215描述。
- 该PTV与GM关系可用于VMAT肺SBRT计划设计与质控的百分位评估。
研究设计与样本
- 观察R50%与PTV大小的关系,对照RTOG 0915与0813约束区分次要和重大偏差。
- 采用最小二乘回归确定梯度测量(GM)对PTV依赖的幂函数系数。
主要发现
- 317例周边型肺SBRT计划中,142例无偏差、135例次要偏差、40例重大偏差(按RTOG 0915剂量学适形性和剂量跌落约束)。
- 排除RTOG 0915重大偏差后,周边病灶的GM与PTV关系拟合为GM=0.564 V^0.215。
关键数值与推荐
- RTOG 0915与0813约束用于判定计划的次要偏差与重大偏差。
- 拟合公式GM=0.564 V^0.215用于描述周边型肺SBRT计划GM随PTV的变化。
- PTV<85 cm3的计划可参照既往计划给出百分位GM进行主观评估。
临床怎么用
- 在VMAT肺SBRT计划设计与质控中,可依据PTV大小用GM=0.564 V^0.215评估剂量梯度是否合理。
- 对PTV<85 cm3的计划,可对照既往计划给出百分位GM辅助主观评价。
- 应同时关注RTOG 0915/0813约束下的偏差分级,而非仅依赖梯度指标。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The treatment of lung lesions with stereotactic body radiation therapy calls for highly conformal dose, which is evaluated by a number of metrics. Lung stereotactic body radiation therapy clinical trials constrain a plans gradient index. The purpose of this work is to describe the dependence of clinically achievable dose gradient on planning target volume. METHODS: Three hundred seventy-four lung stereotactic body radiation therapy treatment plans were retrospectively reviewed and selected for this study. The relationship between R50% and planning target volume size was observed and compared against the RTOG 0915 and 0813 constraints noting minor and major deviations. Then a least squares regression was used to determine the coefficients for a power functional form of the dependence of gradient measure (GM) on planning target volume size. RESULTS: Of the 317 peripheral lung SBRT plans, 142 exhibited no deviation, 135 exhibited a minor deviation, and 40 exhibited a major deviation according to the RTOG 0915 dosimetric. conformality and dose fall-off constraints. A plot of gradient measure versus planning target volume size for peripheral lesions, excluding RTOG 0915 major deviations, is fit with an power function of GM = 0.564 V0.215. CONCLUSIONS: Using the PTV size and GM relationship we have characterized, treatment plans with PTV < 85 cm3 can be evaluated subjectively to our previously plans, and given a percentile GM. This relationship and evaluation is useful for volumetric modulated arc therapy lung stereotactic body radiation therapy treatment planning and quality control.
引用
- Hoffman D, Dragojević I, Hoisak J, et al. Lung Stereotactic Body Radiation Therapy (SBRT) dose gradient and PTV volume: a retrospective multi-center analysis. Radiat Oncol. 2019. PMID: 31481089. doi:10.1186/s13014-019-1334-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。