宫颈癌MRI头尾方向肿瘤大小与病理对照的前瞻性验证:MPAC研究
结果显示镜下肿瘤向宫底延伸在MRI可见肿瘤周围10 mm范围内,术后器官形态改变是测量不确定性的主要来源。
要点
- 镜下肿瘤向宫底延伸在MRI可见肿瘤周围10 mm范围内。
- 术后器官形态改变是测量不确定性的主要来源。
- 非刚性配准后,MRI肿瘤周围10 mm边缘可覆盖90%患者95%的肿瘤。
核心结论
- 镜下肿瘤向宫底延伸在MRI可见肿瘤周围10 mm范围内。
- 术后器官形态改变是测量不确定性的主要来源。
研究设计与样本
- 方法一:两名放射科医生在MRI上测量头尾方向肿瘤延伸,与病理医生显微镜测量比较。
- 方法二:为补偿术前MRI与手术标本间子宫形态变化,由放疗医生和住院医师直接比较头尾方向肿瘤延伸,视为三维肿瘤的一部分。
- 方法三:对两种模态的子宫、宫腔和肿瘤进行数字非刚性配准后,比较MRI肿瘤大小与宏观病理。
主要发现
- 病理 minus MRI头尾方向肿瘤延伸:放射科医生测量与显微镜延伸相比平均+3 mm(范围-13至+15 mm)。
- 放疗医生评估MRI与宏观肿瘤相比平均-0.2 mm(范围-11至+6.0 mm)。
- 非刚性器官配准后,MRI肿瘤周围10 mm边缘可覆盖90%患者中95%的肿瘤。
关键数值与推荐
- 镜下肿瘤向宫底延伸在MRI可见肿瘤周围10 mm范围内。
- 非刚性配准后,MRI肿瘤周围10 mm边缘覆盖90%患者中95%的肿瘤。
临床怎么用
- 早期宫颈癌术前MRI评估头尾方向肿瘤延伸时,应考虑可见肿瘤周围10 mm边缘以覆盖镜下延伸。
- 术后器官形态改变是测量不确定性的主要来源,解读MRI与病理差异时需考虑此因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine the accuracy of MRI in detecting craniocaudal tumour extension, compared to histopathology, of the hysterectomy specimen in patients with early-stage uterine cervical cancer. Three complementary methods were investigated. MATERIALS AND METHODS: Thirty-four patients with early-stage cervical cancer had pre-operative MRI, followed by radical hysterectomy or trachelectomy. 1) craniocaudal tumour extension was measured on MRI by two radiologists and compared to microscopy by a pathologist, 2) to compensate for changes in uterine shape between pre-operative MRI and the surgical specimen, craniocaudal tumour extensions were directly compared and appreciated as being a part of a 3-dimensional tumour by a radiation oncologist and resident, and 3) tumour size on MRI was compared macroscopically after digital non-rigid registration of the uterus, uterine cavity and tumour of both modalities. RESULTS: The craniocaudal tumour extension measured on histopathology minus MRI gives: 1) on average +3 mm difference when measured by a radiologist compared to the microscopic extension (range -13 to +15 mm), 2) -0.2 mm (range -11 to +6.0 mm) when evaluated on MRI by a radiation oncologist compared to the macroscopic tumour; 3) after non-rigid organ registration, a margin of 10 mm around the tumour on MRI would be needed to cover 95% of the tumour in 90% of the patients. CONCLUSIONS: Results indicate that microscopic tumour extension towards the uterine fundus is within a margin of 10 mm around the visible tumour on MRI. The major source of measurement uncertainty is post-surgical change of organ shape and form.
引用
- de Boer P, Spijkerboer AM, Bleeker MCG, et al. Prospective validation of craniocaudal tumour size on MR imaging compared to histoPAthology in patients with uterine cervical cancer: The MPAC study. Clin Transl Radiat Oncol. 2019. PMID: 31341971. doi:10.1016/j.ctro.2019.06.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。