CNAO碳离子放疗视神经约束:报告并与欧洲与日本RBE关联
BACKGROUND AND PURPOSE: Until now, carbon ion RT (CIRT) dose constraints for the optic nerve (ON) have only been validated and reported in the NIRS RBE-weighted dose (DNIRS).…
要点
- 旧约束下56条视神经视力保留,3条出现视力下降。
- 视力下降对应DLEM|1%≥71 Gy(RBE)/DLEM|20%≥68 Gy(RBE)。
核心结论
- 通过分析CNAO毒性数据并关联NIRS和GSI/HIT经验,推导出视神经的新DLEM约束。
- 研究证明在DLEM和DNIRS两种RBE加权剂量下重新计算并报告结果具有价值。
研究设计与样本
- 回顾性分析2013-14年在CNAO接受头颈部碳离子放疗的38例患者共65条视神经。
- 复现治疗计划吸收剂量并分别应用DLEM和DNIRS,将CNAO临床毒性与DNIRS关联。
- 中位随访47(26-67)个月。
主要发现
- 旧约束被遵守的56条视神经视力保留。
- 3条视神经出现视力下降,对应DLEM|1%≥71 Gy(RBE)/DLEM|20%≥68 Gy(RBE)。
- 上述视力下降对应DNIRS|1%≥68 Gy(RBE)/DNIRS|20%≥62 Gy(RBE)。
关键数值与推荐
- NIRS约束DNIRS|1%≤40 Gy(RBE)/DNIRS|20%≤28 Gy(RBE)对应DLEM|1%≤50 Gy(RBE)/DLEM|20%≤40 Gy(RBE)。
- 按新DLEM约束重新优化计划后,以DNIRS评估仍符合NIRS约束。
临床怎么用
- 头颈部碳离子放疗规划视神经时可采用CNAO新实施的DLEM约束。
- 评估计划时可同时在DLEM和DNIRS下报告剂量以关联NIRS经验。
局限性
- 研究指出方法存在不确定性,因此未直接采用推导的较宽松约束而实施较温和的约束。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Until now, carbon ion RT (CIRT) dose constraints for the optic nerve (ON) have only been validated and reported in the NIRS RBE-weighted dose (DNIRS). The aim of this work is to improve CNAO's RBE-weighted dose (DLEM) constraints by analyzing institutional toxicity data and by relating it to DNIRS. MATERIAL AND METHODS: A total of 65 ONs from 38 patients treated with CIRT to the head and neck region in the period 2013-14 were analyzed. The absorbed dose (DAbs) of the treatment plans was reproduced and subsequently both DLEM and DNIRS were applied, thus relating CNAO clinical toxicity to DNIRS. RESULTS: Median FU was 47 (26-67) months. Visual acuity was preserved for the 56 ONs in which the old constraints were respected. Three ONs developed visual decline at DLEM|1% ≥71 Gy(RBE)/DLEM|20% ≥68 Gy(RBE), corresponding to DNIRS|1% ≥68 Gy(RBE)/DNIRS|20% ≥62 Gy(RBE). Dose recalculation revealed that NIRS constraints of DNIRS|1% ≤40 Gy(RBE)/DNIRS|20% ≤28 Gy(RBE) corresponded to DLEM|1% ≤50 Gy(RBE)/DLEM|20% ≤40 Gy(RBE). Reoptimization of treatment plans with these new DLEM constraints showed that the dose distribution still complied with NIRS constraints when evaluated in DNIRS. However, due to uncertainties in the method, and to comply with the EQD2-based constraints used at GSI/HIT, a more moderate constraint relaxation to DLEM|1% ≤45 Gy(RBE)/DLEM|20% ≤37 Gy(RBE) has been implemented in CNAO clinical routine since October 2018. CONCLUSION: New DLEM constraints for the ON were derived by analyzing CNAO toxicity data and by linking our results to the experience of NIRS and GSI/HIT. This work demonstrates the value of recalculating and reporting results in both DLEM and DNIRS.
引用
- Dale JE, Molinelli S, Vitolo V, et al. Optic nerve constraints for carbon ion RT at CNAO - Reporting and relating outcome to European and Japanese RBE. Radiother Oncol. 2019. PMID: 31310888. doi:10.1016/j.radonc.2019.06.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。