本研究比较两种运动不敏感T2加权MRI序列(MVXD与SSFSE)在前列腺癌MRI模拟定位中对前列腺尿道的显像能力。22例无导尿管患者于3T MRI扫描,两位泌尿生殖放射科医师评分。MVXD序列尿道可见性评分显著优于SSFSE(P<.0001),观察者间一致性高(kappa=0.67)。

要点

  • MVXD序列尿道可见性评分显著高于SSFSE序列(P<.0001)。
  • 两位读者均认为MVXD序列信噪比在所有病例中更优。
  • MVXD伪影更多但多位于周边,不影响尿道显像。

核心结论

  • 径向T2加权多层脉冲序列(MVXD)在前列腺癌磁共振模拟定位中对尿道显像优于SSFSE序列。

研究设计与样本

  • 两位泌尿生殖放射科医师对前列腺尿道可见性进行1至5分评分,并评估信噪比和伪影。

主要发现

  • MVXD序列尿道可见性评分在22例中18例(读者1)和17例(读者2)高于SSFSE序列。
  • MVXD与SSFSE评分差异对两位读者均具有统计学显著性(P<.0001,配对Student t检验)。
  • 观察者间一致性高(Cohen kappa=0.67)。
  • 两位读者均发现MVXD序列信噪比在所有病例中更优。
  • MVXD序列伪影多于SSFSE序列,但伪影多出现在周边且不影响尿道显像能力。

关键数值与推荐

  • 尿道可见性评分采用1至5分制。
  • MVXD与SSFSE评分差异P<.0001(配对Student t检验)。
  • 观察者间一致性Cohen kappa=0.67。

临床怎么用

  • 在前列腺癌MRI模拟定位中,可优先选用径向T2加权多层序列(MVXD)以改善尿道显像,利于尿道保护。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The use of magnetic resonance imaging (MRI) for radiation therapy simulation is growing because of its ability to provide excellent delineation of target tissue and organs at risk. With the use of hypofractionated schemes in prostate cancer, urethral sparing is essential; however, visualization of the prostatic urethra can be challenging because of the presence of benign prostatic hyperplasia as well as respiratory motion artifacts. The goal of this study was to compare the utility of 2 motion-insensitive, T2-weighted MRI pulse sequences for urethra visualization in the setting of MRI-based simulation. METHODS AND MATERIALS: Twenty-two patients undergoing MRI simulation without Foley catheters were imaged on a 3 Tesla MRI scanner between October 2018 and January 2019. Sagittal multislice data were acquired using (1) MultiVane XD radial sampling with parallel imaging acceleration (MVXD) and (2) single-shot fast-spin-echo (SSFSE) sequences with acquisition times of 2 to 3 minutes per sequence. For each examination, 2 genitourinary radiologists scored prostatic urethra visibility on a 1-to-5 scale and rated the signal-to-noise ratio and the presence of artifacts in each series. RESULTS: Urethral visibility was scored higher in the MVXD series than in the SSFSE series in 18 of 22 cases (Reader 1) and 17 of 22 cases (Reader 2). The differences in scores between MVXD and SSFSE were statistically significant for both readers (P < .0001 for both, paired Student's t-test) and interobserver agreement was high (Cohen's kappa = 0.67). Both readers found the signal-to-noise ratio of the MVXD sequence to be superior in all cases. The MVXD sequence was found to generate more artifacts than the SSFSE sequence, but these tended to appear in the periphery and did not affect the ability to visualize the urethra. CONCLUSIONS: A radial T2-weighted multislice pulse sequence was superior to an SSFSE sequence for visualization of the urethra in the setting of magnetic resonance simulation for prostate cancer.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Zakian KL, Wibmer A, Vargas HA, et al. Comparison of Motion-Insensitive T2-Weighted MRI Pulse Sequences for Visualization of the Prostatic Urethra During MR Simulation. Pract Radiat Oncol. 2019. PMID: 31252087. doi:10.1016/j.prro.2019.06.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。