文献速递乳腺癌放疗放疗物理与技术

深吸气屏气用于左侧乳腺癌放疗:剂量-质量直方图分析及肺膨胀影响

Deep inspiration breath-hold for left-sided breast irradiation: Analysis of dose-mass histograms and the impact of lung expansion.
PubMed 文献 · Radiat Oncol · 2019-06-18

研究对比31例左侧乳腺癌患者深吸气屏气(DIBH)与自由呼吸(FB)下的剂量-体积直方图(DVH)和剂量-质量直方图(DMH)参数,并分析肺膨胀和解剖因素与剂量差异的相关性。DIBH降低心脏剂量和多数患者肺剂量,DMH获益需DVH体积获益约≥8-9%,肺膨胀不影响肺剂量但影响心脏剂量。

要点

  • DIBH使左肺Dmean(DVH)平均降低19±9%,V20(%)降低24±10%。
  • DIBH使心脏Dmean降低53%,该获益与肺前向膨胀相关。
  • DVH体积获益约≥8-9%时,DMH质量获益才可实现。

核心结论

  • DIBH降低左侧乳腺癌放疗的心脏剂量和多数患者肺剂量、相对受照肺体积及肺质量,肺膨胀影响心脏剂量而非肺剂量。

研究设计与样本

  • 回顾性研究,31例左侧乳腺癌患者,在FB和DIBH CT上计算3D适形放疗计划,并转入MATLAB计算DVH和DMH。

主要发现

  • DIBH降低左肺Dmean(DVH)平均-19±9%、V20(%)平均-24±10%,DMH的Dmean和M20(%)也显著降低(-12±11%、-16±13%)。
  • 4例患者DIBH下DMH值高于FB。
  • DVH与DMH参数线性回归良好,Dmean(DVH)获益小于8.4%时提示DIBH下受照肺质量高于FB。
  • 左肺平均膨胀:左侧1.5±2.4 mm、前向16.0±4.0 mm、尾向12.2±4.6 mm;膨胀与左肺Dmean差异无显著相关。
  • 心脏Dmean在DIBH下全部患者降低53%,获益与前向肺膨胀相关。

关键数值与推荐

  • DIBH下左肺Dmean(DVH)平均降低19±9%,V20(%)降低24±10%。
  • DIBH下左肺Dmean(DMH)降低12±11%,M20(%)降低16±13%。
  • 心脏Dmean降低53%,与肺前向膨胀相关。
  • DVH体积获益约≥8-9%时,DMH质量获益可实现。

临床怎么用

  • 左侧乳腺癌放疗可考虑DIBH以降低心脏和肺剂量,但需评估DVH体积获益是否≥8-9%以确保质量获益。
  • DIBH时较强的胸式呼吸(前向膨胀)可能比腹式呼吸更有利于降低心脏剂量。

局限性

  • 回顾性研究,样本量31例,部分患者DIBH下DMH值反而更高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to compare dose-volume histogram (DVH) with dose-mass histogram (DMH) parameters for treatment of left-sided breast cancer in deep inspiration breath-hold (DIBH) and free breathing (FB). Additionally, lung expansion and anatomical factors were analyzed and correlated to dose differences. METHODS: For 31 patients 3D conformal radiation therapy plans were retrospectively calculated on FB and DIBH CTs in the treatment planning system. The calculated doses, structures and CT data were transferred into MATLAB and DVHs and DMHs were calculated. Mean doses (Dmean), volumes and masses receiving certain doses (Vx, Mx) were determined for the left lung and the heart. Additionally, expansion of the left lung was evaluated using deformable image registration. Differences in DVH and DMH dose parameters between FB and DIBH were statistically analyzed and correlated to lung expansion and anatomical factors. RESULTS: DIBH reduced Dmean (DVH) and relative V20 (V20 [%]) of the left lung in all patients, on average by - 19 ± 9% (mean ± standard deviation) and - 24 ± 10%. Dmean (DMH) and M20 [%] were also significantly reduced (- 12 ± 11%, - 16 ± 13%), however 4 patients had higher DMH values in DIBH than in FB. Linear regression showed good correlations between DVH and DMH parameters, e.g. a dosimetric benefit smaller than 8.4% for Dmean (DVH) in DIBH indicated more irradiated lung mass in DIBH than in FB. The mean expansion of the left lung between FB and DIBH was 1.5 ± 2.4 mm (left), 16.0 ± 4.0 mm (anterior) and 12.2 ± 4.6 mm (caudal). No significant correlations were found between expansions and differences in Dmean for the left lung. The heart dose in DIBH was reduced in all patients by 53% (Dmean) and this dosimetric benefit correlated to lung expansion in anterior. CONCLUSIONS: Treatment of left-sided breast cancer in DIBH reduced dose to the heart and in most cases the lung dose, relative irradiated lung volume and lung mass. A mass related dosimetric benefit in DIBH can be achieved as long as the volume related benefit is about ≥8-9%. The lung expansion (breathing pattern) showed no impact on lung dose, but on heart dose. A stronger chest breathing (anterior expansion) for DIBH seems to be more beneficial than abdominal breathing.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Oechsner M, Düsberg M, Borm KJ, et al. Deep inspiration breath-hold for left-sided breast irradiation: Analysis of dose-mass histograms and the impact of lung expansion. Radiat Oncol. 2019. PMID: 31215458. doi:10.1186/s13014-019-1293-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。