文献速递乳腺癌放疗放疗物理与技术

利用4DCT扫描制作定制心脏挡块的新技术用于左侧乳腺癌放疗

A New Technique Using 4DCT Scans to Create Custom Cardiac Blocks for Left-Sided Breast Cancer Treatments.
PubMed 文献 · Pract Radiat Oncol · 2019-06-18

该研究对20例左侧乳腺癌患者使用4DCT扫描勾画最大密度投影(MIP)心脏并制作定制心脏挡块,与基于自由呼吸CT的挡块比较。结果显示4D挡块面积平均增加2.58 cm2,多叶准直器覆盖平均增加3.9 mm,心脏受量更高被遮挡。该技术可利用现有4DCT设备在临床实施。

要点

  • 4DCT基于MIP心脏制作的挡块面积大于自由呼吸CT挡块,平均增加2.58 cm2。
  • 多叶准直器覆盖平均增加3.9 mm,范围0.5-20.1 mm。
  • 该技术可利用现有4DCT设备在临床实践中轻松实施。

核心结论

  • 基于4DCT的定制心脏挡块考虑内在呼吸和心脏运动,尺寸大于自由呼吸挡块,能遮挡更多心脏剂量。

研究设计与样本

  • 对20例左侧乳腺癌患者获取4DCT扫描并勾画MIP心脏,制作完全遮挡MIP心脏体积的定制心脏挡块,并与回顾性基于自由呼吸CT制作的挡块比较。

主要发现

  • 全部20例中4D扫描制作的心脏挡块面积均大于对应的自由呼吸挡块。
  • 多叶准直器覆盖平均增加3.9 mm(范围0.5-20.1 mm),心脏挡块面积平均增加2.58 cm2(范围0.22-6.65 cm2)。
  • 剂量体积直方图显示MIP心脏平均比自由呼吸心脏多接受17.8 cGy(范围0.02-70.3 cGy)。
  • 用自由呼吸心脏挡块重新计划后,MIP心脏平均剂量比自由呼吸心脏剂量增加16.2 cGy(范围1.8-44.8 cGy)。

临床怎么用

  • 可利用临床现有4DCT设备制作考虑呼吸和心脏运动的定制心脏挡块,以增加对心脏剂量的遮挡。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: For patients who receive treatment for left breast cancer, cardiac toxicity increases with increased radiation dose to the heart. A new method was developed using 4-dimensional computed tomography (CT) scans to improve custom cardiac blocks to minimize heart dose. METHODS AND MATERIALS: Four-dimensional CT scans were acquired, and a maximum intensity projection (MIP) heart was contoured for 20 patients. Custom heart blocks were created to fully block the MIP heart volume. A heart block based on the standard free-breathing (FB) CT image was retrospectively created. Differences in heart block sizes were compared. Differences in heart block areas and dose statistics were analyzed. RESULTS: In all 20 cases, the heart block created using the 4-dimensional scan had a larger area than the corresponding FB block. The mean increase in multileaf collimator coverage was 3.9 mm (range, 0.5-20.1 mm). The mean increase in the area of the heart block was 2.58 cm2 (range, 0.22-6.65 cm2). The dose-volume histogram showed that the MIP heart received 17.8 cGy (range, 0.02-70.3 cGy) more than the FB heart on average. Replanning with an FB heart block showed that the mean dose to the MIP heart increased by 16.2 cGy (range, 1.8-44.8 cGy) compared with the FB heart dose. CONCLUSIONS: Four-dimensional heart blocks accounting for intrinsic respiratory motion and cardiac motion were greater in size than FB heart blocks. These larger blocks resulted from the larger contour created from the MIP image and blocked more dose to the heart. This technique for improving custom heart blocks can be easily implemented with 4DCT machine capabilities that are currently available in clinical practice.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. DuPre PJ, Fitzherbert CM, Hand CM, et al. A New Technique Using 4DCT Scans to Create Custom Cardiac Blocks for Left-Sided Breast Cancer Treatments. Pract Radiat Oncol. 2019. PMID: 31226442. doi:10.1016/j.prro.2019.06.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。