文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

多参数MRI肿瘤概率模型检测放疗后局部复发前列腺癌:病理验证及与手动勾画的比较

Multiparametric MRI Tumor Probability Model for the Detection of Locally Recurrent Prostate Cancer After Radiation Therapy: Pathologic Validation and Comparison With Manual Tumor Delineations.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2019-05-11

本研究利用放疗后复发前列腺癌患者的多参数MRI训练并独立测试肿瘤概率(TP)模型,以病理切片肿瘤勾画为参考标准。测试队列中模型全前列腺AUC中位数为0.77,模型衍生GTV的敏感性和特异性与两位放射科医师手动勾画无显著差异。基于体素TP的模型可用于放疗后复发前列腺癌局灶挽救治疗靶区定义。

要点

  • mp-MRI训练的TP模型可预测放疗后复发前列腺癌的体素级肿瘤存在,全前列腺AUC中位数0.77。
  • 模型衍生GTV的敏感性和特异性与手动勾画无显著差异。
  • 三级聚类可定义GTV、高危CTV和CTV,风险递增。

核心结论

  • TP模型在预测复发肿瘤体素级存在方面表现良好,模型衍生肿瘤风险水平的敏感性和特异性与手动勾画相似,可用于放疗后复发前列腺癌局灶挽救的靶区定义。

研究设计与样本

  • 训练队列为21例活检证实复发且符合挽救治疗条件的患者,测试队列为17例接受挽救性前列腺切除术的患者,均行mp-MRI(T2加权、扩散加权成像和动态对比增强)。
  • 采用逻辑回归模型训练,以组织病理学衍生肿瘤勾画为参考标准进行测试。
  • 使用k-means聚类体素TP图生成GTV轮廓,与2位放射科医师手动勾画及病理验证轮廓进行体素级比较;另用3聚类定义CTV、高危CTV和GTV。

主要发现

  • 测试队列中模型全前列腺AUC中位数(范围)为0.77(0.41-0.99)。
  • 模型GTV勾画中位敏感性0.31(0-0.87),特异性0.97(0.84-1.0),与手动勾画无显著差异。
  • 三级聚类GTV和高中危CTV勾画的中位敏感性分别为0.17(0-0.59)和0.49(0-0.97),特异性分别为0.98(0.84-1.00)和0.94(0.84-0.99)。

临床怎么用

  • 基于mp-MRI的体素级TP可纳入放疗后复发前列腺癌局灶挽救治疗的靶区定义。
  • 模型衍生肿瘤风险分级可获得与手动勾画相似的定位敏感性和特异性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Focal salvage treatments of recurrent prostate cancer (PCa) after radiation therapy require accurate delineation of the target volume. Magnetic resonance imaging (MRI) is used for this purpose; however, radiation therapy-induced changes complicate image interpretation, and guidelines are lacking on the assessment and delineation of recurrent PCa. A tumor probability (TP) model was trained and independently tested using multiparametric magnetic resonance imaging (mp-MRI) of patients with radio-recurrent PCa. The resulting probability maps were used to derive target regions for radiation therapy treatment planning. METHODS AND MATERIALS: Two cohorts of patients with radio-recurrent PCa were used in this study. All patients underwent mp-MRI (T2 weighted, diffusion-weighted imaging, and dynamic contrast enhanced). A logistic regression model was trained using imaging features from 21 patients with biopsy-proven recurrence who qualified for salvage treatment. The test cohort consisted of 17 patients treated with salvage prostatectomy. The model was tested against histopathology-derived tumor delineations. The voxel-wise TP maps were clustered using k-means to generate a gross tumor volume (GTV) contour for voxel-level comparisons with manual tumor delineations performed by 2 radiologists and with histopathology-validated contours. Later, k-means was used with 3 clusters to define a clinical target volume (CTV), high-risk CTV, and GTV, with increasing tumor risk. RESULTS: In the test cohort, the model obtained a median (range) area under the curve of 0.77 (0.41-0.99) for the whole prostate. The GTV delineation resulted in a median sensitivity of 0.31 (0-0.87) and specificity of 0.97 (0.84-1.0) with no significant differences between model and manual delineations. The 3-level clustering GTV and high-risk CTV delineations had median sensitivities of 0.17 (0-0.59) and 0.49 (0-0.97) and specificities of 0.98 (0.84-1.00) and 0.94 (0.84-0.99), respectively. CONCLUSIONS: The TP model had a good performance in predicting voxel-wise presence of recurrent tumor. Model-derived tumor risk levels achieved sensitivity and specificity similar to manual delineations in localizing recurrent tumor. Voxel-wise TP derived from mp-MRI can in this way be incorporated for target definition in focal salvage of radio-recurrent PCa.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Dinis Fernandes C, Simões R, Ghobadi G, et al. Multiparametric MRI Tumor Probability Model for the Detection of Locally Recurrent Prostate Cancer After Radiation Therapy: Pathologic Validation and Comparison With Manual Tumor Delineations. Int J Radiat Oncol Biol Phys. 2019. PMID: 31085288. doi:10.1016/j.ijrobp.2019.05.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。