3D打印半定制舌推移装置用于头颈部IMRT的研发
本研究利用3D打印技术开发了患者特异性半定制舌推移装置(SCTDD),并在7例头颈癌患者中与标准口含器(SMP)进行剂量学比较。结果显示SCTDD能有效将舌推离计划靶区,显著降低舌中位剂量(29.6 Gy vs. 34.3 Gy)及多个剂量水平的受照体积,有望减少放疗相关舌毒性。
要点
- 3D打印SCTDD由口含器、连接固定架和舌推移器组成,可半定制调整厚度与长度
- SCTDD使舌中位剂量从34.3 Gy降至29.6 Gy
- SCTDD显著降低舌在15、30、35、45、60 Gy的受照体积
核心结论
- SCTDD相比SMP显著降低舌的放疗剂量,可能减少放疗相关舌毒性。
研究设计与样本
- 在7例头颈癌患者中,分别使用SCTDD和SMP获取计划CT及螺旋断层放疗计划,比较剂量学与几何特征。
主要发现
- 使用SCTDD时舌被有效推离计划靶区,且舌体积无显著变化。
- 舌中位剂量显著降低(29.6 Gy vs. 34.3 Gy)。
- 舌接受15 Gy、30 Gy、35 Gy、45 Gy和60 Gy的体积均显著低于SMP。
关键数值与推荐
- 舌中位剂量:SCTDD组29.6 Gy,SMP组34.3 Gy。
- 舌V15、V30、V35、V45、V60在SCTDD组均显著低于SMP组。
临床怎么用
- 头颈癌IMRT中可考虑使用3D打印半定制舌推移装置以降低舌受照剂量。
局限性
- 样本量仅7例,需更大规模研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To reduce radiation doses to the tongue, a patient-specific semi-customized tongue displacement device (SCTDD) was developed using a 3D printer (3DP) for head and neck (H&N) radiation therapy (RT). Dosimetric characteristics of the SCTDD were compared with those of a standard mouthpiece (SMP). MATERIALS AND METHODS: The SCTDD consists of three parts: a mouthpiece, connector with an immobilization mask, and tongue displacer, which can displace the tongue to the contralateral side of the planning target volume. Semi-customization was enabled by changing the thickness and length of the SCTDD. The instrument was printed using a 3DP with a biocompatible material. With the SCTDD and SMP, two sets of planning computed tomography (CT) and tomotherapy plans were obtained for seven H&N cancer patients. Dosimetric and geometric characteristics were compared. RESULTS: Using the SCTDD, the tongue was effectively displaced from the planning target volume without significant tongue volume change compared to the SMP. The median tongue dose was significantly reduced (29.6 Gy vs. 34.3 Gy). The volumes of the tongue receiving a dose of 15 Gy, 30 Gy, 35 Gy, 45 Gy, and 60 Gy were significantly lower than using the SMP. CONCLUSION: The SCTDD significantly decreased the radiation dose to the tongue compared to the SMP, which may potentially reduce RT-related tongue toxicity.
引用
- Hong CS, Oh D, Ju SG, et al. Development of a semi-customized tongue displacement device using a 3D printer for head and neck IMRT. Radiat Oncol. 2019. PMID: 31088472. doi:10.1186/s13014-019-1289-x